2012
DOI: 10.1016/j.chroma.2012.03.089
|View full text |Cite
|
Sign up to set email alerts
|

Extension of the liquid chromatography/quantitative structure–property relationship method to assess the lipophilicity of neutral, acidic, basic and amphotheric drugs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 22 publications
(14 citation statements)
references
References 46 publications
0
14
0
Order By: Relevance
“…The chromatographic hydrophobicity index (CHI) developed by Valko et al can be used as an independent measure of hydrophobicity [44] and offers a simple way to evaluate the log P of a drug [45]. In fact, the need to correct chromatographic measurements with the hydrogen bond acidity to get reliable log P values has been demonstrated recently [42,46]. This is a remarkable feature since pure chromatographic methods only offer good estimations of log P for compounds without significant hydrogen bond acidity.…”
Section: Measuring Lipophilicitymentioning
confidence: 97%
“…The chromatographic hydrophobicity index (CHI) developed by Valko et al can be used as an independent measure of hydrophobicity [44] and offers a simple way to evaluate the log P of a drug [45]. In fact, the need to correct chromatographic measurements with the hydrogen bond acidity to get reliable log P values has been demonstrated recently [42,46]. This is a remarkable feature since pure chromatographic methods only offer good estimations of log P for compounds without significant hydrogen bond acidity.…”
Section: Measuring Lipophilicitymentioning
confidence: 97%
“…The guidelines about log D 7.4 values and their implication for drug development are illustrated in Table 1 (Comer, 2003;Taylor and Triggle, 2007). There are many different approaches which can be used to determine a partition coefficient experimentally (Avdeef, 1993;Donovan and Pescatore, 2002;Gulyaeva et al, 2008;Hitzel et al, n.d.;Kaliszan et al, 2002;Pallicer et al, 2012Pallicer et al, , 2010Ràfols et al, 2012;Stopher and Mcclean, 1990;Takács-Novák and Avdeef, 1996;Valko et al, 2001;Wiczling et al, 2008), but the most direct one is the shake-flask method. In this method, an aqueous solution of a compound is mixed in a flask with an organic solvent (usually water saturated n-octanol).…”
Section: Introductionmentioning
confidence: 98%
“…The partition coefficient (P) refers to the ratio of compound concentration in each phase and can be determined experimentally by a variety of methods including the well-known shake-flask method (EPA, 1996;OECD 107 Method, 1995), potentiometric methods (Avdeef, 1993(Avdeef, , 1992Ràfols et al, 2012;Takács-Novák and Avdeef, 1996), chromatographic methods (Donovan and Pescatore, 2002;Kaliszan et al, 2002;Liang and Lian, 2015;OECD 117 Method, 2004;Pallicer et al, 2012Pallicer et al, , 2010Wiczling et al, 2008) and others. Besides, lipophilicity can also be estimated using computer software and extensive studies about the accuracy of calculated log P values by different computer software has already been carried out (Chou and Jurs, 1979;Leo, 1987;Mannhold et al, 2009;Pallicer et al, 2014;Tetko et al, 2009).…”
Section: Introductionmentioning
confidence: 99%
“…The used simplified approach involves only one descriptor, the Abraham's A parameter, which can be easily estimated from the compound structure using either a commercial software package (ACD/Labs) or the open access UFZ-LSER Database (Ulrich et al, 2017). It was proved that this method is able to properly estimate log Po/w values from -1 to 7 (Pallicer et al, 2012), broadening in two orders of magnitude the lipophilicity range proposed in previous guidelines (OECD, 2004). d) Two potentiometric titrations of the drug, with and without n-octanol, allow the log Po/w determination of compounds with acid-base properties.…”
Section: Prior Remarks: Techniques Log Po/w Ranges and Ionization Omentioning
confidence: 78%