2017
DOI: 10.1152/japplphysiol.00734.2016
|View full text |Cite
|
Sign up to set email alerts
|

Exposure-response modeling of flow-mediated dilation provides an unbiased and informative measure of endothelial function

Abstract: The brachial artery flow-mediated dilation (FMD) test is the most widely utilized method to evaluate endothelial function noninvasively in humans by calculating the percent change in diameter (FMD%). However, the underutilized velocity and diameter time course data, coupled with confounding influences in shear exposure, noise, and upward bias, make the FMD test less desirable. In this study, we developed an exposure-response, model-based approach that not only quantifies FMD based on the rich velocity and diam… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(8 citation statements)
references
References 25 publications
0
8
0
Order By: Relevance
“…Brachial artery FMD was measured using a standardized technique. 10 All subjects were studied in the morning, having abstained from alcohol, caffeine and food for 12 h before the test. The diameter of the artery was measured using high-resolution, two-dimensional ultrasound images obtained with a Doppler ultrasound device (HDI-ATL 5000, USA) with a 5 MHz to 12 MHz linear-array transducer.…”
Section: Methodsmentioning
confidence: 99%
“…Brachial artery FMD was measured using a standardized technique. 10 All subjects were studied in the morning, having abstained from alcohol, caffeine and food for 12 h before the test. The diameter of the artery was measured using high-resolution, two-dimensional ultrasound images obtained with a Doppler ultrasound device (HDI-ATL 5000, USA) with a 5 MHz to 12 MHz linear-array transducer.…”
Section: Methodsmentioning
confidence: 99%
“…Aside from modeling the NO delivery from the small-scale mechanism, other studies modeled this process in large scale. For example, the exposure-response model was established based on the simplified physical formula to describe the NO delivery and vasodilation, which uniquely considers the FMD time course and excludes the interference of shear-exposure from the endothelial function [64]. This model was recently extended to quantitatively reveal the interfaces of blood pressure and arterial stiffness on assessing the endothelial function from FMD% [65,66].…”
Section: Mathematical Modeling Of No Delivery In Flow-mediated Dilation To Enhance the Specificity Of Endothelial Functionmentioning
confidence: 99%
“…There have been a few numerical models describing different physiological and hemodynamic aspects of the FMD test (4,34,38). Yamazaki et al (38) developed a mathematical model of the WSS-dependent vasomotor response involving both intra-and intercellular pathways, which was able to reproduce typical changes in arterial wall diameter during the FMD test.…”
Section: Introductionmentioning
confidence: 99%
“…They used the model to quantify changes in Young's modulus and peripheral resistance during the FMD test. In a recent study, Van Brackle et al (34) developed a model-based exposure response method for quantification of physiologically meaningful parameters that describe both the WSS exposure and diameter response during the FMD test and which was used in our study. None of these models were used to investigate the biophysical confounding factors studied here that may affect the FMD test results.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation