2013
DOI: 10.1093/eurheartj/eht308.p2344
|View full text |Cite
|
Sign up to set email alerts
|

Exposure reduction by optimization of the imaging toolchain in pulmonary vein isolation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…Dose–area product (DAP) rate is a figure of merit used to compare absorbed doses in real medical imaging 67 . DAP rate of around 2.5 Gy air cm 2 h −1 is estimated for perovskite detector in interventional cardiology with X-rays continuously on for capturing an image (entrance area of 100 cm 2 ) of the human body, at least an order of magnitude better than that offered by state-of-the-art commercial medical radiographic systems 68,69 . The resolution of X-ray image reached 10 lp mm −1 , which is comparable to those of the best CZT X-ray detectors and CsI(Tl) scintillator detectors as shown in Table 1, and is still lower than α-Se flat panel imagers 70 .…”
Section: Advance In the Development Of Perovskite X-ray Imaging Detecmentioning
confidence: 99%
“…Dose–area product (DAP) rate is a figure of merit used to compare absorbed doses in real medical imaging 67 . DAP rate of around 2.5 Gy air cm 2 h −1 is estimated for perovskite detector in interventional cardiology with X-rays continuously on for capturing an image (entrance area of 100 cm 2 ) of the human body, at least an order of magnitude better than that offered by state-of-the-art commercial medical radiographic systems 68,69 . The resolution of X-ray image reached 10 lp mm −1 , which is comparable to those of the best CZT X-ray detectors and CsI(Tl) scintillator detectors as shown in Table 1, and is still lower than α-Se flat panel imagers 70 .…”
Section: Advance In the Development Of Perovskite X-ray Imaging Detecmentioning
confidence: 99%
“…Compared with CT, patient radiation exposure is reduced and can be brought to levels well below accepted values for interventional procedures. 10 A workflow based on imaging in the EP lab allows logistic independence from other departments, making 'on the spot' decision trees possible. In addition, cost benefits are reasonable to expect as the incremental cost of performing a single 3DRA amounts to contrast agent and a pigtail catheter.…”
Section: Three-dimensional Rotational Angiography As Computed Tomogramentioning
confidence: 99%