Proceedings of the Genetic and Evolutionary Computation Conference 2017
DOI: 10.1145/3071178.3071311
|View full text |Cite
|
Sign up to set email alerts
|

Exploring trade-offs between target coverage, healthy tissue sparing, and the placement of catheters in HDR brachytherapy for prostate cancer using a novel multi-objective model-based mixed-integer evolutionary algorithm

Abstract: Brachytherapy is a form of radiotherapy whereby a radiation source is guided near tumors, using devices such as catheter implants. In the present clinical work ow, catheters are rst placed inside or close to the tumor based on clinical expertise. Subsequently, soware is used to design a plan for the delivery of radiation. Treatment planning is essentially a multi-objective optimization problem, where con icting objectives represent radiation delivered to tumor cells and healthy cells. However, current clinical… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
26
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
4
1
1

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(26 citation statements)
references
References 12 publications
(16 reference statements)
0
26
0
Order By: Relevance
“…This requires 5, 4, and 5 catheters for patients 1, 2, and 3, respectively. For comparison, the Pareto fronts presented in [11] required 7, 7, and 14 catheters, respectively. The treatment plans that were clinically used for these patients are all outside the Golden Corner.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…This requires 5, 4, and 5 catheters for patients 1, 2, and 3, respectively. For comparison, the Pareto fronts presented in [11] required 7, 7, and 14 catheters, respectively. The treatment plans that were clinically used for these patients are all outside the Golden Corner.…”
Section: Resultsmentioning
confidence: 99%
“…The results are compared to the results obtained with GAMBIT in [11]. These results were reported to have been obtained with a duration of optimization limited to 48 hours per catheter number.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Real-world optimisation problems often exhibit a so called observation uncertainty, because physical measurements usually contain errors [4]. This uncertainty can cause issues, especially if the application is sensitive, such as in case of medical treatments [111]. Research in the field of noisy optimisation and real-world applications targets this and related issues.…”
Section: Motivationmentioning