Abstract: We report a detailed investigation on the use of chelators PYTAM, H4PYTAMGly, CHX-PYTAM and H4CHX-PYTAMGly for the complexation of Pb(II)-radioisotopes with potential use in the preparation of radiopharmaceuticals. The macrocyclic...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 85 publications
0
2
0
Order By: Relevance
“…The preparation of ligands PYAN and CHXPYAN was carried out following previously reported procedures. , While the Mn­(II) complex of PYAN was previously reported as the bromide salt, to the best of our knowledge, through a search of the CCDC database, the CHXPYAN complex had not. Reaction of the ligands with Mn­(NO 3 ) 2 in ethanol afforded the corresponding water-soluble Mn­(II) complexes, with high-resolution mass spectra and high-performance liquid chromatography (HPLC) analysis confirming their formation (Figures S1–S4, Supporting Information).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The preparation of ligands PYAN and CHXPYAN was carried out following previously reported procedures. , While the Mn­(II) complex of PYAN was previously reported as the bromide salt, to the best of our knowledge, through a search of the CCDC database, the CHXPYAN complex had not. Reaction of the ligands with Mn­(NO 3 ) 2 in ethanol afforded the corresponding water-soluble Mn­(II) complexes, with high-resolution mass spectra and high-performance liquid chromatography (HPLC) analysis confirming their formation (Figures S1–S4, Supporting Information).…”
Section: Resultsmentioning
confidence: 99%
“…The solvents and reagents were of reagent grade and were purchased from commercial sources and used without further purification. Chelators PYAN and CHXPYAN were prepared according to previously reported procedures. , Both chelators were purified by semipreparative HPLC using H 2 O and CH 3 CN + 0.1% formic acid as the mobile phases to ensure sufficient purity for radiolabeling experiments (Table S2, Supporting Information).…”
Section: Methodsmentioning
confidence: 99%