2021
DOI: 10.1177/09544062211007524
|View full text |Cite
|
Sign up to set email alerts
|

Exploiting the instability of eccentric tube robots for distal force control in minimally invasive cardiac ablation

Abstract: While the dilemma of motion tracking and force control in beating-heart surgery is previously addressed using active control architectures and rigid robotic actuators, this work leverages the highly controllable mechanical properties of concentric tube robots for intelligent, design-based force control in minimally invasive cardiac ablation. Briefly, cardiac ablation is the conventional procedure for treating arrhythmia patients, by which exposing the diseased cardiac tissue to Radio-Frequency (RF) energy rest… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
0
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(1 citation statement)
references
References 47 publications
(44 reference statements)
0
0
0
Order By: Relevance
“…However, the drawbacks of electric heating are: (1) the requirement for a specific setup, which has some hardware limitations (2) tuning and calibrating the system to match the tube-specific transition temperature is challenging, and (3) the uneven thermal gradient/expansion along the tube can result in undesirable distorted shapes near the clamped ends [114]. Despite the high cost and inefficiency, the most commonly used approach is still the furnace heating technique, as recorded in 24 papers [35], [46], [62], [70], [81]- [83], [90], [120]- [135], as compared to the electric heating with only 6 papers [11], [114], [136]- [139], while both approaches are recorded in [80], [119], [140].…”
Section: B Tube Fabricationmentioning
confidence: 99%
“…However, the drawbacks of electric heating are: (1) the requirement for a specific setup, which has some hardware limitations (2) tuning and calibrating the system to match the tube-specific transition temperature is challenging, and (3) the uneven thermal gradient/expansion along the tube can result in undesirable distorted shapes near the clamped ends [114]. Despite the high cost and inefficiency, the most commonly used approach is still the furnace heating technique, as recorded in 24 papers [35], [46], [62], [70], [81]- [83], [90], [120]- [135], as compared to the electric heating with only 6 papers [11], [114], [136]- [139], while both approaches are recorded in [80], [119], [140].…”
Section: B Tube Fabricationmentioning
confidence: 99%