2021
DOI: 10.1016/j.matdes.2021.109593
|View full text |Cite
|
Sign up to set email alerts
|

Experimentally validated constitutive model for NiTi-based shape memory alloys featuring intermediate R-phase transformation: A case study of Ni48Ti49Fe3

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 16 publications
(8 citation statements)
references
References 62 publications
0
8
0
Order By: Relevance
“… Comparison of work output as a function of actuation response temperature upon cooling (i.e., Mnormals) for the Ti49.2Ni50.8xCox alloys with different Co contents and other reported shape‐memory alloys, including Ti–Ni binary, [ 13,17,18,43–45 ] Ti–Ni–Cu based, [ 46,47 ] Ti–Ni–Pd based, [ 48,49 ] Ti–Ni–Hf based, [ 50–53 ] Ti–Ni–Fe, [ 54,55 ] and Cu–Al–Mn [ 11 ] alloys.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“… Comparison of work output as a function of actuation response temperature upon cooling (i.e., Mnormals) for the Ti49.2Ni50.8xCox alloys with different Co contents and other reported shape‐memory alloys, including Ti–Ni binary, [ 13,17,18,43–45 ] Ti–Ni–Cu based, [ 46,47 ] Ti–Ni–Pd based, [ 48,49 ] Ti–Ni–Hf based, [ 50–53 ] Ti–Ni–Fe, [ 54,55 ] and Cu–Al–Mn [ 11 ] alloys.…”
Section: Resultsmentioning
confidence: 99%
“…[29,31] The distinct deformation behaviors among Co1, Co4, and Co6 are likely due to their different microstructures, which are shown in Section 2.5. [13,17,18,[43][44][45] Ti-Ni-Cu based, [46,47] Ti-Ni-Pd based, [48,49] Ti-Ni-Hf based, [50][51][52][53] Ti-Ni-Fe, [54,55] and Cu-Al-Mn [11] alloys.…”
Section: In Situ Digital Image Correlation Observation Of Strain Resp...mentioning
confidence: 99%
“…The proper fixation of samples in the grips affects the measurement accuracy [27,28]. Similar grips are used in other universal testing machines [18,[21][22][23]. Two types of fixing the samples are presented in figure 4.…”
Section: Preparing the Device For Operationmentioning
confidence: 99%
“…The horizontal sample allows using the microscope on a standard stand without additional brackets or consoles, opposite to vertical stationary universal tensile testing machines [16,21,26]. This sample arrangement allows maintaining the device's compactness, versatility, and portability.…”
Section: Preparing the Device For Operationmentioning
confidence: 99%
See 1 more Smart Citation