2016
DOI: 10.1063/1.4965953
|View full text |Cite
|
Sign up to set email alerts
|

Experimental verification of the crack opening displacement using finite element method for CT specimens made of Ti6Al4V titanium alloy

Abstract: Description of fatigue crack growth in steel structural components using energy approachInfluence of the microstructure on the FCGR AIP Conference Proceedings 1780, 050003 (2016) Abstract When determining the characteristics of the fatigue crack growth rate, it is necessary, inter alia, to measure the crack length growth which must be combined with the number of accumulated load cycles. The length of the crack is determined using different testing methods. Recently, there is an increased interest in optical sy… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 7 publications
0
6
0
Order By: Relevance
“…When the crack grows to a certain degree, the maximum stress intensity reaches the fracture threshold, and the crack commences to deteriorate rapidly following a fracture mechanism rather than a fatigue mechanism [40,41]. As a result, most part of the crack behaves as a linear scatterer which prevents the probing GUW from traversing the crack, leading to reduced intensity of CAN and therefore decreasing NI, as observed in Fig.…”
Section: (C)mentioning
confidence: 90%
“…When the crack grows to a certain degree, the maximum stress intensity reaches the fracture threshold, and the crack commences to deteriorate rapidly following a fracture mechanism rather than a fatigue mechanism [40,41]. As a result, most part of the crack behaves as a linear scatterer which prevents the probing GUW from traversing the crack, leading to reduced intensity of CAN and therefore decreasing NI, as observed in Fig.…”
Section: (C)mentioning
confidence: 90%
“…Its efficiency was verified through comparison of the calculation results with the results of optical measurement and through FEA analysis. 31…”
Section: Methodsmentioning
confidence: 99%
“…The method of operation software was presented in figure 3. Detailed information about the system operation can be found in the article [6]. It should be noted that the crack opening displacement was carried out by placing a CT sample extensometer in the lock, as shown in figure 2.…”
Section: Test Conditionsmentioning
confidence: 99%