2013
DOI: 10.1016/j.mechatronics.2012.03.007
|View full text |Cite
|
Sign up to set email alerts
|

Experimental validation of the linear drive train for a total artificial heart system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
6
1

Relationship

4
3

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 6 publications
0
5
0
Order By: Relevance
“…A sinusoidal displacement with a systole-diastole time ratio of 1:1, a peak-to-peak amplitude of 18 mm and a frequency of 100 bpm (0.6 s for one pump cycle) was applied to the pusher plate. This frequency was chosen for this study because the pump runs with at least 100 bpm to achieve the required perfusion of 6 l/min (20) and, therefore, the worst washout is expected. The ratio of 1:1 was evaluated in vitro to be the most efficient operation point as far as acceleration, stroke volume, and left-right flow balance are concerned.…”
Section: Methodsmentioning
confidence: 99%
“…A sinusoidal displacement with a systole-diastole time ratio of 1:1, a peak-to-peak amplitude of 18 mm and a frequency of 100 bpm (0.6 s for one pump cycle) was applied to the pusher plate. This frequency was chosen for this study because the pump runs with at least 100 bpm to achieve the required perfusion of 6 l/min (20) and, therefore, the worst washout is expected. The ratio of 1:1 was evaluated in vitro to be the most efficient operation point as far as acceleration, stroke volume, and left-right flow balance are concerned.…”
Section: Methodsmentioning
confidence: 99%
“…[3][4][5] The development of a patented linear actuator formed the basis for the TAH ReinHeart. [6][7][8] The TAH replaces the function of the natural heart and is implanted as an orthotopic heart replacement with complete excision of both ventricles. Several studies have demonstrated the proof of concept, as well as initial results in terms of durability, 9 hemocompatibility, 10 implantable driver electronics, 11,12 and preliminary in vivo performance.…”
Section: Introductionmentioning
confidence: 99%
“…For several decades, the research on an artificial heart replacement has been carried out at the Helmholtz Institute in Aachen 3‐5 . The development of a patented linear actuator formed the basis for the TAH ReinHeart 6‐8 . The TAH replaces the function of the natural heart and is implanted as an orthotopic heart replacement with complete excision of both ventricles.…”
Section: Introductionmentioning
confidence: 99%
“…In addition, electrical machines are integrated into a wide variety of environments, e.g. as in total artificial heart [2]. As a result, each design of an electrical machine is based on individual requirements and boundary conditions.…”
Section: Introductionmentioning
confidence: 99%