2023
DOI: 10.3390/s23094320
|View full text |Cite
|
Sign up to set email alerts
|

Experimental Validation of High Spatial Resolution of Two-Color Optical Fiber Pyrometer

Abstract: Taking non-contact temperature measurements in narrow areas or confined spaces of non-uniform surfaces requires high spatial resolution and independence of emissivity uncertainties that conventional cameras can hardly provide. Two-color optical fiber (OF) pyrometers based on standard single-mode (SMF) and multi-mode optical fibers (MMF) with a small core diameter and low numerical aperture in combination with associated commercially available components can provide a spatial resolution in the micrometer range,… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
1
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 34 publications
0
1
0
Order By: Relevance
“…Next, the system was installed in the technological line of the corrugator and configured. Continuous measurement of the surface temperature of paper or cardboard requires the use of non-contact measurement techniques [ 31 , 32 , 33 ]. The system consists of pyrometers and immersion thermometers, a corrugator speed transducer, and recorders of measured values connected to a local computer network.…”
Section: Methodsmentioning
confidence: 99%
“…Next, the system was installed in the technological line of the corrugator and configured. Continuous measurement of the surface temperature of paper or cardboard requires the use of non-contact measurement techniques [ 31 , 32 , 33 ]. The system consists of pyrometers and immersion thermometers, a corrugator speed transducer, and recorders of measured values connected to a local computer network.…”
Section: Methodsmentioning
confidence: 99%
“…Finally, to verify the model experimental measurements will be carried out in future works using small targets as those reported in [23]. Substituting ( 17) in ( 16), and solving for θ max , it is found that:…”
Section: Critical Distance As a Function Of Tilting Anglementioning
confidence: 97%
“…Finally, to verify the model experimental measurements will be carried out in future works using small targets as those reported in [23].…”
Section: Critical Distance As a Function Of Tilting Anglementioning
confidence: 99%
See 1 more Smart Citation