2008
DOI: 10.1299/jbse.3.161
|View full text |Cite
|
Sign up to set email alerts
|

Experimental Validation of Color Doppler Velocity Measurement for Ultrasonic-Measurement-Integrated Simulation of Blood Flow

Abstract: Cardiovascular diseases are closely related to blood flow. Ultrasonic-Measurement-Integrated (UMI) simulation, in which results of ultrasonic measurement are fed back to the flow simulation, was proposed in a previous study in order to reproduce the real blood flow accurately and efficiently. The usability of the UMI simulation was confirmed by numerical experiment, but the effectiveness of this simulation was strongly affected by the accuracy of the ultrasonic measurement. In this paper, we examined the accur… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2014
2014
2014
2014

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 26 publications
(26 reference statements)
0
2
0
Order By: Relevance
“…Results and discussion Figure 2 shows variations of the acoustic properties of PVA gel for ultrasound with the PVA concentration, c PVA , at a constant DMSO concentration of c DMSO = 48 mol% without glass beads (c particle = 0 mass%). These PVA gels are comparable to those used to create flow phantoms in former studies [27,28]. The acoustic properties do not approximate those of in vivo soft tissue, implying that PVA gels are not suitable for tissue-mimicking.…”
Section: Flow Experimentsmentioning
confidence: 57%
See 1 more Smart Citation
“…Results and discussion Figure 2 shows variations of the acoustic properties of PVA gel for ultrasound with the PVA concentration, c PVA , at a constant DMSO concentration of c DMSO = 48 mol% without glass beads (c particle = 0 mass%). These PVA gels are comparable to those used to create flow phantoms in former studies [27,28]. The acoustic properties do not approximate those of in vivo soft tissue, implying that PVA gels are not suitable for tissue-mimicking.…”
Section: Flow Experimentsmentioning
confidence: 57%
“…PVA gel shows fine optical transparency with the addition of dimethyl sulfoxide (DMSO) [26]. Transparent PVA gel flow phantoms have been developed for the training of medical personnel in catheter intervention for cerebral aneurysms [27] and for experimental validation of ultrasound color Doppler measurement with conventional medical ultrasonic equipment [28]. However, the appropriateness of the acoustic properties of those transparent PVA gels has not been examined.…”
Section: Introductionmentioning
confidence: 99%