2016 10th International Conference on Compatibility, Power Electronics and Power Engineering (CPE-POWERENG) 2016
DOI: 10.1109/cpe.2016.7544218
|View full text |Cite
|
Sign up to set email alerts
|

Experimental test results of the 150kVA 18-pulse diode rectifier with series active power filter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 7 publications
0
6
0
Order By: Relevance
“…In literature, 6-pulse or 12-pulse diode rectifiers are commonly described (with 18 and 24 pulse present as well [46,[50][51][52][53]). The first is built as a 6 pulse diode bridge consisting of six uncontrollable diodes and a low-pass filter for smoothing the DC current [54].…”
Section: Hvdc Diode Rectifier Unitmentioning
confidence: 99%
“…In literature, 6-pulse or 12-pulse diode rectifiers are commonly described (with 18 and 24 pulse present as well [46,[50][51][52][53]). The first is built as a 6 pulse diode bridge consisting of six uncontrollable diodes and a low-pass filter for smoothing the DC current [54].…”
Section: Hvdc Diode Rectifier Unitmentioning
confidence: 99%
“…A simplified schematic diagram of the analyzed ac/dc supply system is shown in Figure 1. Several control methods of the S-APF connected to the input of a multipulse rectifier are presented in the literature [8][9][10][11][12]. The first developed control algorithms were implemented using analogue control techniques [8,9].…”
Section: Converter System Characteristicmentioning
confidence: 99%
“…Digital control of S-APF as a current source based on the hysteresis controller was proposed in [11] by the authors of this article. In [12] instead of current controllers with a large bandwidth, proportional-integral controllers in multiple reference frames were used for selective line current harmonic suppression.…”
Section: Introductionmentioning
confidence: 99%
“…powering conditions (network, accumulator batteries) and EMC impact on the network. work safety and comfort maintenance and air conditioning conditions (temperature range of work, humidity, altitude) reliability (application demands) (Mysiak P., 2010), (Mysiak P. et al, 2016). The main issue with designing can be boiled down to analysis of assumptions, requirements, and possible solutions affordable in the current state of technology.…”
Section: Selected Regulations and Recommendations Concerning The Consmentioning
confidence: 99%