Experimental study on uniaxial ratchetting of VHB 4910 dielectric elastomer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(3 citation statements)
references
References 23 publications
0
2
0
Order By: Relevance
“…Based on Supplementary Fig. 27, the hysteresis values of M p , M p-w-p , M w , and M w-p-w sensors were calculated as 18, 27, 28, and 31, respectively, as the hysteresis of a VHB tape increased with the applied strains of 5%, 15%, 25%, and 40% 44,45 . Fabrication reproducibility is highly critical for wearable sensor applications, as the users can avoid re-calibration of as-fabricated M n sensors and use the in-database S ε -ε profiles as the references 23,46,47 .…”
Section: Crack Propagation Behaviors Of M N Sensors With Homogenous A...mentioning
confidence: 99%
“…Based on Supplementary Fig. 27, the hysteresis values of M p , M p-w-p , M w , and M w-p-w sensors were calculated as 18, 27, 28, and 31, respectively, as the hysteresis of a VHB tape increased with the applied strains of 5%, 15%, 25%, and 40% 44,45 . Fabrication reproducibility is highly critical for wearable sensor applications, as the users can avoid re-calibration of as-fabricated M n sensors and use the in-database S ε -ε profiles as the references 23,46,47 .…”
Section: Crack Propagation Behaviors Of M N Sensors With Homogenous A...mentioning
confidence: 99%
“…However, traditional approach of determining the dielectric constant upon stretching is ex situ and clumsy. In these approaches, the samples with predetermined area were stretched by clamping them in a frame, following which the electrodes were prepared and the capacitance was measured to determine the dielectric constant [21][22][23]. Based on the above methods, the sample thickness measurement is not accurate, and the tensile strain is difficult to measure accurately [18].…”
Section: Introductionmentioning
confidence: 99%
“…However, the traditional approach for determining the dielectric constant upon stretching is ex situ and clumsy. In these approaches, samples with a predetermined area were stretched by clamping them in a frame, following which the electrodes were prepared and the capacitance was measured to determine the dielectric constant [ 21 , 22 , 23 ]. Based on the above methods, the sample thickness measurement is not accurate, and the tensile strain is difficult to measure accurately [ 18 ].…”
Section: Introductionmentioning
confidence: 99%