2008
DOI: 10.1002/lsm.20647
|View full text |Cite
|
Sign up to set email alerts
|

Experimental study on thermic effects, morphology and function of guinea pig cochlea: A comparison between the erbium:yttrium–aluminum–garnet laser and carbon dioxide laser

Abstract: The Er:YAG and CO(2) lasers are shown to be safe if the total amount of energy is kept within the limits applied in this study. In addition, on this preliminary basis by guinea pig laser cochleostomy, Er:YAG laser maybe less damaging to inner ear structures than CO(2) laser with a larger safety scope and less thermic effects.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 13 publications
(8 citation statements)
references
References 21 publications
(35 reference statements)
0
8
0
Order By: Relevance
“…The specific role that thermal damage plays in preservation of residual cochlear function is unknown. Similar to stapes surgery, minimizing thermal injury would be ideal during cochlear implantation 8. A major advantage of the CO 2 laser is the characteristic shallow depth of penetration in water of ∼10 μm 6.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The specific role that thermal damage plays in preservation of residual cochlear function is unknown. Similar to stapes surgery, minimizing thermal injury would be ideal during cochlear implantation 8. A major advantage of the CO 2 laser is the characteristic shallow depth of penetration in water of ∼10 μm 6.…”
Section: Discussionmentioning
confidence: 99%
“…Similar to stapes surgery, minimizing thermal injury would be ideal during cochlear implantation. 8 A major advantage of the CO 2 laser is the characteristic shallow depth of penetration in water of 10 lm. 6 The immediate absorption by fluid prevents deeper penetration to vulnerable cochlear structures.…”
Section: Discussionmentioning
confidence: 99%
“…The detection procedure was well documented in our previous article [6]. A 0.8 mm diameter detecting head was placed onto the membrane of the round window to measure the temperature change at approximately one pulse per second during laser irradiation in vivo.…”
Section: Methodsmentioning
confidence: 99%
“…The laser source may either be continuous wave such as carbon dioxide lasers or pulsed lasers such as erbium:yttriumaluminium-garnet (Er:YAG), erbium:yttrium-scandiumgallium-garnet (Er:YSGG) and holmium:YAG. 25 Provided in their study involves the safety in relevance to total energy distribution and thermal generation with respect to laser irradiation towards the guinea pig cochlea.…”
Section: Consideration Of Laser Parameters Can Affect the Outcome Of ...mentioning
confidence: 99%