2011
DOI: 10.1016/j.applthermaleng.2011.01.030
|View full text |Cite
|
Sign up to set email alerts
|

Experimental study on the operating characteristics of a novel low-concentrating solar photovoltaic/thermal integrated heat pump water heating system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
27
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 101 publications
(27 citation statements)
references
References 12 publications
0
27
0
Order By: Relevance
“…Therefore, the deviation of the performance calculated by the model discussed in the previous section and the interpolating curve is basically due to the fact that, in the proposed model, the overall heat transfer coefficients are not constant and vary with the CPVT operating conditions. Conversely, there is not a good correlation between the electrical efficiency and the parameter shown in Equation (25). In fact, the electrical efficiency of the CPVT basically depends on the operating temperature of the PV layer and on the concentration ratio, as shown in Equation (11).…”
Section: Resultsmentioning
confidence: 97%
See 2 more Smart Citations
“…Therefore, the deviation of the performance calculated by the model discussed in the previous section and the interpolating curve is basically due to the fact that, in the proposed model, the overall heat transfer coefficients are not constant and vary with the CPVT operating conditions. Conversely, there is not a good correlation between the electrical efficiency and the parameter shown in Equation (25). In fact, the electrical efficiency of the CPVT basically depends on the operating temperature of the PV layer and on the concentration ratio, as shown in Equation (11).…”
Section: Resultsmentioning
confidence: 97%
“…On the basis of the CPVT model discussed in the previous section, electrical and thermal efficiencies were analyzed as a function of the parameter shown below [34]: (25) The result of this analysis is shown in Figure 2. Here, it is clearly shown that the correlation between the thermal efficiency and the above mentioned parameter is very good.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Xu et al [26] developed a low-concentrating PVT integrated heat pump system with both electricity and heat outputs. Fixed truncated parabolic concentrators with geometrical concentration ratio of 2.44 x were adopted [26]. Moreover, a roof-integrated concentration solar system for a self-sustainable Mediterranean villa, the Astonyshine house, was investigated [27].…”
Section: Introductionmentioning
confidence: 99%
“…The optical unit was based on a stationary wide angle optical concentrator which transmitted the input radiation into a small moving focal area, which in turn was tracked by the solar absorber [25]. Xu et al [26] developed a low-concentrating PVT integrated heat pump system with both electricity and heat outputs. Fixed truncated parabolic concentrators with geometrical concentration ratio of 2.44 x were adopted [26].…”
Section: Introductionmentioning
confidence: 99%