2021
DOI: 10.1016/j.csite.2021.101210
|View full text |Cite
|
Sign up to set email alerts
|

Experimental study on the heat transport capability of micro-grooved oscillating heat pipe

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 37 publications
0
4
0
Order By: Relevance
“…The maximum equivalent thermal conductivity is about 1977 W/(m•K) when the partition wall is located in the middle of the channel. Qu J et al [114] studied the heat transfer performance under vertical heating based on micro groove PHP and the maximum effective thermal conductivity of PHP was 41.8 kW/(m• • C) at 40% filling rate. Lim J et al [115] tested the influence of the channel arrangement on the plate MPHP under local heating.…”
Section: Heat Transfer Performance Improvement Of Pipeline Structurementioning
confidence: 99%
See 1 more Smart Citation
“…The maximum equivalent thermal conductivity is about 1977 W/(m•K) when the partition wall is located in the middle of the channel. Qu J et al [114] studied the heat transfer performance under vertical heating based on micro groove PHP and the maximum effective thermal conductivity of PHP was 41.8 kW/(m• • C) at 40% filling rate. Lim J et al [115] tested the influence of the channel arrangement on the plate MPHP under local heating.…”
Section: Heat Transfer Performance Improvement Of Pipeline Structurementioning
confidence: 99%
“…Work Medium/Structure Performance Improvement MPHP with cavity [112] Ethanol/With concave cavity ↓57% of thermal resistance Micro slot PHP [114] Water/Separation wall The maximum allowable input heat flux is increased by 90 times FPPHP [118,119] Water/Secondary bubble ↓11-20% of thermal resistance Yeboah et al [127] designed an experiment for testing the copper spiral OHP with ethanol, methanol and deionized water as work fluids. Ebrahimi et al [128] added interconnection channels in FP-PHP to enhance heat transfer and increased the working power range of FP-PHP.…”
Section: Php Speciesmentioning
confidence: 99%
“…Therefore, micro-grooved OHP is one of the effective modes to evaluate the performance heat transfer of the system. This device would enhance the allowable input heat flux by condensate the backflow to the evaporator when the filling ratio ranging from 30% to 60% [1]. Due to increase in filling ratio, heat added to the evaporator section leads to increase in temperature and pressure during the flow process.…”
Section: Introductionmentioning
confidence: 99%
“…So, the flow of working fluid in pulsating heat pipe originated due to the oscillation and phase change phenomenon of the working fluid. The PHP has various applications in microelectronics cooling, solar system and automotive technology (Qu et al 2021;Agha 2011).…”
Section: Introductionmentioning
confidence: 99%