2018
DOI: 10.1016/j.expthermflusci.2018.07.030
|View full text |Cite
|
Sign up to set email alerts
|

Experimental study on heat transfer and pressure drop of twisted oval tube bundle in cross flow

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
8
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 42 publications
(8 citation statements)
references
References 29 publications
0
8
0
Order By: Relevance
“…Yin [1,2] and others studied the three-dimensional tube evaporator and condenser in the field of refrigeration, and found that the three-dimensional tube evaporator and condenser have a positive impact on the COP (coefficient of performance) of the refrigeration unit. The results show that the heat transfer performance of the three-dimensional tube is better than that of the smooth tube after Xiuzhen Li et al [3][4][5], who studied the heat transfer performance (coefficient of performance) of the refrigeration unit. The results show that the heat transfer performance of the three-dimensional tube is better than that of the smooth tube after Xiuzhen Li et al [3][4][5], who studied the heat transfer performance of a three-dimensional tube bundle with lateral air scour.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Yin [1,2] and others studied the three-dimensional tube evaporator and condenser in the field of refrigeration, and found that the three-dimensional tube evaporator and condenser have a positive impact on the COP (coefficient of performance) of the refrigeration unit. The results show that the heat transfer performance of the three-dimensional tube is better than that of the smooth tube after Xiuzhen Li et al [3][4][5], who studied the heat transfer performance (coefficient of performance) of the refrigeration unit. The results show that the heat transfer performance of the three-dimensional tube is better than that of the smooth tube after Xiuzhen Li et al [3][4][5], who studied the heat transfer performance of a three-dimensional tube bundle with lateral air scour.…”
Section: Introductionmentioning
confidence: 99%
“…The results show that the heat transfer performance of the three-dimensional tube is better than that of the smooth tube after Xiuzhen Li et al [3][4][5], who studied the heat transfer performance (coefficient of performance) of the refrigeration unit. The results show that the heat transfer performance of the three-dimensional tube is better than that of the smooth tube after Xiuzhen Li et al [3][4][5], who studied the heat transfer performance of a three-dimensional tube bundle with lateral air scour. Based on the analysis of the comprehensive heat transfer performance and the law of the three-dimensional tube used in the shell and tube heat exchanger and flue gas heat exchanger by Xun Mo et al [6][7][8], it is concluded that the comprehensive performance of the three-dimensional tube is the best among several kinds of enhanced tubes.…”
Section: Introductionmentioning
confidence: 99%
“…Nevertheless, there was a great difference in the fluid FPD for different particle size and shape in packed beds. In addition, the existing fluid FPD correlations in particle-packed beds were mainly in the form of Ergun's equation and f p , while the FPD correlation in the form of Euler number (Eu) only appeared in the study of FPD in heat exchangers [31][32][33]. Based on an authors' literature survey, there is almost no research to investigate the fluid FPD correlation in the form of Eu in particle-packed beds.…”
Section: Introductionmentioning
confidence: 99%
“…Terukazu et al (1984) indicated that the efficiency of the elliptical tube is better than the circular tube. Li et al (2018) investigated the efficiency of elliptical tubes experimentally in the Reynolds numbers from 7,500 to 18,000. Their results indicated the superiority of these types of tubes rather than circular tubes.…”
Section: Introductionmentioning
confidence: 99%
“…Experimental results revealed that the twisted elliptical tubes provided substantial heat transfer enhancement accompanies with high-pressure drop. Li et al (2018) presented an experimental investigation on air side pressure drop, heat transfer and performance bundle of the twisted oval tube having staggered arrangement in crossflow. This research showed that the performance of the studied bundle of the twisted oval tubes is greater than that of the round tube bundle.…”
Section: Introductionmentioning
confidence: 99%