Abstract:In order to clarify the relationship between the efficacy loss of strain clamp joints and the crimping quality, three groups of clamp joints, crimped under unbalanced conditions at both ends, naming NY-240/40, NY-400/35 and NY-630/45 were selected and then subjected to tensile tests and X-ray inspection. After a detailed analysis of the experimental results, it can be seen that under the condition of unbalanced crimping quality, the efficacy loss all occurred on the side with better crimping quality, which pro… Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.