2022
DOI: 10.1088/2058-6272/ac64f1
|View full text |Cite
|
Sign up to set email alerts
|

Experimental study of single-translated field-reversed configuration in KMAX

Abstract: For the collisional merging field reversed configurations (FRCs), it is desired to have both FRCs to be tuned approximately same, as well as to optimize each FRC to have high temperature, and high translation speed so as to retain most of the equilibrium flux after traveling a distance to the middle plane for merging. The present study reports the experimental study of a single-translated FRC (field-reversed configuration) in the KMAX-FRC device with various diagnostics, including a triple probe, a bolometer, … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 30 publications
0
6
0
Order By: Relevance
“…As expected, FRC has a hollow while θ-pinch plasma has a peaked density profile. The FRC is accelerated into the central cell by magnetic gradient, and the translation speed v z of plasma can be estimated by time-of-flight method from the APD array or the B e array in KMAX [30,33]. In this experiment, the estimated v z of north FRC is about 60 km s −1 , which is near or slightly larger than the Alfvén speed.…”
Section: Typical Parameter Of Single-translated North Frc and South θ...mentioning
confidence: 87%
See 1 more Smart Citation
“…As expected, FRC has a hollow while θ-pinch plasma has a peaked density profile. The FRC is accelerated into the central cell by magnetic gradient, and the translation speed v z of plasma can be estimated by time-of-flight method from the APD array or the B e array in KMAX [30,33]. In this experiment, the estimated v z of north FRC is about 60 km s −1 , which is near or slightly larger than the Alfvén speed.…”
Section: Typical Parameter Of Single-translated North Frc and South θ...mentioning
confidence: 87%
“…where r w denotes the wall radius, B 0 (B e ) represents the external background magnetic field without (with) the FRC passing through. The 2D magnetic probe array [30], which is located at the device's mid-plane, has a total of 32 measurement points (four points in the radial direction and eight points in the axial direction); each detection point has two pickup coils installed orthogonally for B z and B r measurements, and the distance between each detection point is 5 cm. The bolometer located at Z = −0.25 m consists of 16-channel AXUV array (AXUV16ELG), and the flux loop installed at Z = 0.33 m has a diameter of 0.7 m.…”
Section: Diagnosticsmentioning
confidence: 99%
“…The produced main compression field has a rise-time of ∼5 µs and a peak value of ∼1400 G. Upon reaching maximum current, a crowbar switch is finally closed to slow down the decay of the coil current. When FRC is formed and ejected from the formation section, it expands and translates into the confinement chamber along the magnetic field line at a constant speed, v z = 60 km s −1 , which is near or slightly larger than the Alfvén speed [18], the typical parameters of single-translated FRC at device's mid-plane, such as electron density, electron temperature, ion temperature, separatrix radius, separatrix length and poloidal flux estimated by the rigid-rotor (RR) model [23] are n e ∼ (2-4) × 10 19 m −3 , T e ∼ 8 eV, T i ∼ 5 eV, r s ∼ 0.2 m, l s ∼ 0.6 m and ϕ p(RR) ∼0.2 mWb [18].…”
Section: Experimental Device and Diagnosticsmentioning
confidence: 99%
“…The spatial resolution of the probe, in either the R or Z direction, is 5 cm. Note that the 2D magnetic probe array has been carried out in the single-translated FRC experiment and has demonstrated good performance [18]. Other crucial diagnostics used in this experiment include: the B e (external magnetic field) array consists of 12 magnetic probes equally distributed along the axis from Z = −0.825 m to Z = 0.825 m and the triple probe located at Z = 0.…”
Section: Experimental Device and Diagnosticsmentioning
confidence: 99%
See 1 more Smart Citation