2019
DOI: 10.1016/j.conbuildmat.2019.03.055
|View full text |Cite
|
Sign up to set email alerts
|

Experimental study of RC deep beams with opening and FRP composites installed by means of EBR and EBROG methods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
29
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 29 publications
(30 citation statements)
references
References 28 publications
1
29
0
Order By: Relevance
“…In this study, 0.21-mm thick woven carbon fiber fabrics that consisted of 3k filaments were used as reinforcement. The average density of the carbon fiber fabrics was 1.76 g/cm 3 . The tensile strength, elastic modulus, and ultimate tensile strain of the carbon-fiber fabrics were 3530 MPa, 230,000 MPa, and 1.5%, respectively, as provided by the manufacturer.…”
Section: Materials Propertiesmentioning
confidence: 99%
See 2 more Smart Citations
“…In this study, 0.21-mm thick woven carbon fiber fabrics that consisted of 3k filaments were used as reinforcement. The average density of the carbon fiber fabrics was 1.76 g/cm 3 . The tensile strength, elastic modulus, and ultimate tensile strain of the carbon-fiber fabrics were 3530 MPa, 230,000 MPa, and 1.5%, respectively, as provided by the manufacturer.…”
Section: Materials Propertiesmentioning
confidence: 99%
“…where n is the number of plies, A w (= 198 g/m 2 ) is the fiber areal weight, ρ f (= 1.76 g/cm 3 ) is the fiber density, and h is the specimen thickness. In the case of the first series, the carbon fiber volume fractions of CFRP0-0, S-MWCNT-COOH-CFRP0-0, MWCNT-CFRP0-0, and GnPs-CFRP0-0 were 40.61%, 39.31%, 38.35%, and 39.94%, respectively.…”
Section: Carbon-fiber Volume Fractionmentioning
confidence: 99%
See 1 more Smart Citation
“…In our literature review, it has been pointed out that the openings diminish RC deep beams' bearing capacity [29][30][31]. Openings of RC deep beams can be used to pass electrical, mechanical, and architectural equipment.…”
Section: Introductionmentioning
confidence: 99%
“…eir results showed that the FRP strengthening system was rather effective in avoiding shear failure and confining the web chords. In addition to partial reinforcing methods, other scholars [15][16][17] investigated additional strengthening methods to compensate for the effect of web openings.…”
Section: Introductionmentioning
confidence: 99%