2018
DOI: 10.1016/j.est.2018.01.015
|View full text |Cite
|
Sign up to set email alerts
|

Experimental study of internal and external short circuits of commercial automotive pouch lithium-ion cells

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
33
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 93 publications
(43 citation statements)
references
References 11 publications
0
33
0
Order By: Relevance
“…An internal short circuit occurs when the insulating separator layer between the electrodes fails. This failure of the separator can be attributed to melting due to high temperature, cell deformation, the formation of dendrite, or compressive shock [7,19,20]. All of these can cause penetration through the separator layer, or cause the lithium ions and electrons to be released at the anode and travel across the electrolyte toward the cathode, which triggers contact between the anode and the cathode, leading to internal short-circuiting.…”
Section: Internal Short Circuitmentioning
confidence: 99%
“…An internal short circuit occurs when the insulating separator layer between the electrodes fails. This failure of the separator can be attributed to melting due to high temperature, cell deformation, the formation of dendrite, or compressive shock [7,19,20]. All of these can cause penetration through the separator layer, or cause the lithium ions and electrons to be released at the anode and travel across the electrolyte toward the cathode, which triggers contact between the anode and the cathode, leading to internal short-circuiting.…”
Section: Internal Short Circuitmentioning
confidence: 99%
“…Recently, many studies have been aimed at detecting external short circuit (ESCr) and ISCr in lithium-ion batteries. When the ESCr (R ISCr < 5.4 m ) exists in the batteries, significant changes in measurements such as decrease in terminal voltage and increase in both current and temperature are monitored in short time [12]. ESCr detection methods are developed via using the aforementioned evident changes [13]- [18].…”
Section: Abbreviationsmentioning
confidence: 99%
“…After estimating the R ISCr s with the various SOC(p)s and the fixed SOC ini online, a representative value among the estimates of R ISCr should be determined as a final fault index R fi to detect the soft ISCr. The mean value R ISCr of diverse R end s is calculated in (11) where R end denotes the R ISCr estimated at the last iteration with a SOC(p) and h is the number of R end s. In (12), d denotes deviation of the R end and is then calculated. The R end which has the largest d is considered as an outlier.…”
Section: Final Fault Index Calculationmentioning
confidence: 99%
“…Based on multiphysics model of the LIBs, efficient thermal management system and cooling strategies for LIBs are proposed in References 36‐38. Exploration of short‐circuit modes . In addition to finite element models of LIBs, some exploration of short‐circuit modes 39 and mechanisms has been identified through experiments, 40 numerical simulations, and analyses 41,42 …”
Section: Introductionmentioning
confidence: 99%