2020
DOI: 10.1016/j.buildenv.2020.107205
|View full text |Cite
|
Sign up to set email alerts
|

Experimental study of airborne particle transmission through the doorway of a cleanroom due to the movement of a person

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
5
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(7 citation statements)
references
References 29 publications
1
5
0
1
Order By: Relevance
“…A study of pharmaceutical cleanrooms found that with the door from the anteroom closed, no particles entered the cleanroom due to the overpressure of 15 Pa and few particles entered with door opening and closing. When an individual entered the cleanroom walking fast at 1 m/s with low air flows (210 L/s), contamination was tripled compared to a lower speed of 0.5 m/s and a high air flow of 580 L/second [84]. Another study using a particle generator showed a marked increase in particle concentration within a patient room with the aerosol simulating coughing.…”
Section: Increasing the Use Of Medical Or Surgical Masks And Hand Hygiene To Reduce The Transmission Of Respiratory Virusesmentioning
confidence: 99%
“…A study of pharmaceutical cleanrooms found that with the door from the anteroom closed, no particles entered the cleanroom due to the overpressure of 15 Pa and few particles entered with door opening and closing. When an individual entered the cleanroom walking fast at 1 m/s with low air flows (210 L/s), contamination was tripled compared to a lower speed of 0.5 m/s and a high air flow of 580 L/second [84]. Another study using a particle generator showed a marked increase in particle concentration within a patient room with the aerosol simulating coughing.…”
Section: Increasing the Use Of Medical Or Surgical Masks And Hand Hygiene To Reduce The Transmission Of Respiratory Virusesmentioning
confidence: 99%
“…Cleanroom merupakan ruangan yang dirancang dan dibuat dengan menggunakan teknologi tertentu untuk dapat mengontrol konsentrasi partikel di udara dan partikel pembawa mikroba [1] [2] [3]. Cleanroom dapat melindungi produk elektronik, personal dan peralatan elektronik dari berbagai kontaminan udara melalui daerah yang bersih/kualitas udara yang bersih dan terkontrol.…”
Section: Pendahuluanunclassified
“…With a high enough supply-exhaust flow rate differential, the directional airflow may be sustained also across an open doorway. Although high directional airflows can be disturbed by the door opening motion, occupant movement, temperature difference, turbulence etc., they may still substantially reduce the air volume exchange and hence also the airborne contaminant dispersion through the doorway (Shaw, 1976;Hayden et al, 1998;Shao et al, 2020). Nevertheless, optimal airflow rates through doorways to control cross-contamination are still unknown and additional studies taking into account the effects of dynamic events (such as the door opening and occupant movement) when applying directional airflow are needed.…”
Section: Experimental Studies On the Exchange Flows Through Doorwaysmentioning
confidence: 99%
“…Studies investigating the effect of occupant movement in conjunction with a door opening are much more limited. However, it has been shown that the occupant movement can contribute notably to contaminant transmission through the doorway between adjacent zones (Shaw, 1976;Hayden et al,1998;Tang et al, 2013;Chang et al, 2016;Shao et al, 2020). For instance, Shaw (1976) estimated the amount of air that a fast and slowly walking person transfers through a doorway.…”
Section: Experimental Studies On the Exchange Flows Through Doorwaysmentioning
confidence: 99%
See 1 more Smart Citation