2013
DOI: 10.1016/j.jcsr.2012.12.001
|View full text |Cite
|
Sign up to set email alerts
|

Experimental shear resistance evaluation of Y-type perfobond rib shear connector

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
42
0
1

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 75 publications
(43 citation statements)
references
References 13 publications
0
42
0
1
Order By: Relevance
“…The ductility of the stubby Y-type perfobond rib shear connector with transverse rebar D16 was 45.1% greater than that with D13. According to the assessment criteria for ductility provided by Kim et al (2013), the ductility of the stubby Y-type perfobond rib shear connector with transverse rebar D16 was also 28.8% greater than that with D13. These results show that, when stubby Y-type perfobond rib shear connectors with identical rib sizes are used in composite frame structures, the structures with larger-diameter transverse rebars are preferable in terms of ductility.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…The ductility of the stubby Y-type perfobond rib shear connector with transverse rebar D16 was 45.1% greater than that with D13. According to the assessment criteria for ductility provided by Kim et al (2013), the ductility of the stubby Y-type perfobond rib shear connector with transverse rebar D16 was also 28.8% greater than that with D13. These results show that, when stubby Y-type perfobond rib shear connectors with identical rib sizes are used in composite frame structures, the structures with larger-diameter transverse rebars are preferable in terms of ductility.…”
Section: Discussionmentioning
confidence: 99%
“…Eurocode-4 [37] defines a shear connector as ductile if δuk > 6 mm. In addition, Kim et al [32] suggested using the ratio of the slip capacity and initial relative slip (δu/δ90) to estimate the ductility in the inelastic behavior region of a shear connector by considering initial stiffness. Moreover, Kim et al [35] proposed Equation (1) to predict the shear strength of a Y-type perfobond rib shear connector.…”
Section: Shear Strength and Ductility Of Composite Structures Using Smentioning
confidence: 99%
See 2 more Smart Citations
“…2016, 6, 317 2 of 11 concrete by [4]. Since then, it has been extensively utilized in the construction industry and developed into various forms by many researchers [5][6][7][8][9].…”
Section: Introductionmentioning
confidence: 99%