2011
DOI: 10.1063/1.3658300
|View full text |Cite
|
Sign up to set email alerts
|

Experimental Set-Up to Evaluate the Degradation of the Optical Components of a CPV Module

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
3
0

Year Published

2014
2014
2018
2018

Publication Types

Select...
5
1

Relationship

3
3

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…Three lenses were made in PMMA, three lenses were made in SOG, all lens sets were sent in parallel to the laboratories in Refs. [2,3,4], and measured according to the Method available there.…”
Section: Setupmentioning
confidence: 99%
“…Three lenses were made in PMMA, three lenses were made in SOG, all lens sets were sent in parallel to the laboratories in Refs. [2,3,4], and measured according to the Method available there.…”
Section: Setupmentioning
confidence: 99%
“…The spectral characteristics of the light source seem to differ for almost every setup. Monochromatic light sources of several wavelengths are reported in literature [14][15][16]18] as well as several kinds of polychromatic light sources [19], which makes the comparison of measurement results difficult Mostly four types of sensors are used to measure the irradiation in the focal plane. Some setups use CCD sensors [16], others use a diffusing screen in the focal plane and a camera to take an image of the screen [17,[20][21][22][23].…”
Section: Characterization Of Flux Distribution In the Focal Planementioning
confidence: 99%
“…Because a diffusing screen can be smaller than a CCD camera and is not as sensible to high temperatures a screen may be placed in positions that are not suitable for CCD sensors, but using a diffusing screen results in a loss of spatial and magnitude resolution due to the diffusor structure and light scattered back onto the sample [22,23]. Other setups directly use a solar cell [21,24] or a spectrometer [19,25] as detector. These only allow measuring the optical efficiency as a single number unless a scanning light source is used or the focal plane is scanned with a small aperture in front of the detector.…”
Section: Characterization Of Flux Distribution In the Focal Planementioning
confidence: 99%
“…A straightforward way is the use of spectroradiometers (Bengoechea et al, 2011), but it has inherent difficulties for CPV optics that we will detail here. Firstly, the aforementioned sources of errors related to non-linearity and non-uniformity of the sensor are worsened here because the spectroradiometer probe is usually smaller than the light spot.…”
Section: Wavelength Resolved Efficiencymentioning
confidence: 99%