Experimental research on the cooling performance of a new regenerative dew point indirect evaporative cooler

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(4 citation statements)
references
References 12 publications
0
3
0
Order By: Relevance
“…The heated air stream then passes through the desiccant wheel (7-8) and removes the absorbed water. In the HDH desalination cycle, the inlet air (10) consists of the moist waste air from the rotary desiccant wheel (8) and the M-cycle cooler (9). This mixed air is sent to the humidifier, where it is further humidified and heated by the heated brine (10)(11).…”
Section: Ventilation Modementioning
confidence: 99%
See 1 more Smart Citation
“…The heated air stream then passes through the desiccant wheel (7-8) and removes the absorbed water. In the HDH desalination cycle, the inlet air (10) consists of the moist waste air from the rotary desiccant wheel (8) and the M-cycle cooler (9). This mixed air is sent to the humidifier, where it is further humidified and heated by the heated brine (10)(11).…”
Section: Ventilation Modementioning
confidence: 99%
“…This technology eliminates the need for chemical refrigerants and mechanical compressors, as the cooling process is completed by water evaporation [7]. In 2002, a novel thermodynamic cycle of IEC was developed by Maisotsenko, also known as the M-cycle [8]. In this cycle, a fraction of the pre-cooled supply air is redirected to wet channels as the working air, allowing the product air to be cooled below the WBT and towards the dew point temperature (DPT) of the incoming air at a constant humidity level [9,10].…”
Section: Introductionmentioning
confidence: 99%
“…DIEC heat exchangers, such as traditional IEC systems, can operate in counter-flow and cross-flow configurations, but the counter-flow arrangement is the most common one. As the DIEC technology appears to be very promising, its performance have been thoroughly studied by means of in-depth experimental investigations [57,58], by performing an energy and exergy analysis [59], and also through the artificial neural network method [60]. Moreover, new types of coatings [61] and geometries [62] of the plates have been investigated, and the DIEC system has been integrated into other more complex heat exchangers [63,64], in order to improve its performance.…”
Section: Diec Systemsmentioning
confidence: 99%
“…Its condensation method is not enough to achieve the dehumidification goal [7]. Chu et al [8] found that the heat transfer performance of a regenerative indirect evaporative cooler (RIEC) is not prominent in wet areas. On the other hand, the reduced vapor pressure difference of LDD at high temperatures compromises its dehumidification efficacy [9].…”
Section: Introductionmentioning
confidence: 99%