2019
DOI: 10.1109/tsg.2017.2757599
|View full text |Cite
|
Sign up to set email alerts
|

Experimental Performance of an Islanding Detection Scheme Based on Modal Components

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
26
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 62 publications
(28 citation statements)
references
References 30 publications
0
26
0
Order By: Relevance
“…An importance value of the ordered module preference sets is defined as {1/2, 1/4, 1/8, …, 1/2 x }. Thereafter, the importance of the module x by users u is finally obtained as in (15), where ρ x i is the module x importance value for the ith user subjected to the constraints ∑ I x = 1 and 0 < I x < 1…”
Section: Importance Estimation Of the Modulesmentioning
confidence: 99%
“…An importance value of the ordered module preference sets is defined as {1/2, 1/4, 1/8, …, 1/2 x }. Thereafter, the importance of the module x by users u is finally obtained as in (15), where ρ x i is the module x importance value for the ith user subjected to the constraints ∑ I x = 1 and 0 < I x < 1…”
Section: Importance Estimation Of the Modulesmentioning
confidence: 99%
“…1, pp. [22][23][24][25][26][27][28][29][30][31] This is an open access article published by the IET and Tianjin University under the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0/) presented in [20]. The scheme is successfully tested for islanding detection under perfect power balance condition; however, it is not verified under the noisy scenario.…”
Section: Introductionmentioning
confidence: 99%
“…The most important issue of the DG systems connected to the power grid is the islanding phenomenon [3,4]. Islanding occurs when DG systems and loads are disconnected from the power grid but continue to dispatch the generated power energy to the loads [5,6]. In other words, when the load power and the generated power of the DG systems are balanced, i.e., the load power is fully supplied by DG systems, the islanding phenomenon occurs.…”
Section: Introductionmentioning
confidence: 99%
“…However, the serious drawback of the passive methods is that when the generated power of the inverter-based DG systems and the load power are balanced, a large non-detection zone (NDZ) will make the passive method fail [12,13]. On the other hand, the active methods involve injecting a perturbation signal into the inverter-based DG systems via suitable control algorithms [3,4,6]. Although the perturbation signals are injected into the inverter-based DG system which operates in grid-connected mode, the active islanding detection methods have no significant influence on the system [6].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation