Experimental measurements of Stark widths for Mn I lines in long laser spark

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0
1

Year Published

2017
2017
2022
2022

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 18 publications
(9 citation statements)
references
References 36 publications
0
8
0
1
Order By: Relevance
“…The self-absorption effects were estimated to be about 10%. Furthermore, in 2016 Popov et al [88] estimated the Stark widths of 6 Mn I lines. The LIBS experiments were conducted on an aluminum alloy target containing 80 ppm of manganese, to avoid strong self-absorption of Mn I lines.…”
Section: Determination Of Stark Broadening Coefficientsmentioning
confidence: 99%
“…The self-absorption effects were estimated to be about 10%. Furthermore, in 2016 Popov et al [88] estimated the Stark widths of 6 Mn I lines. The LIBS experiments were conducted on an aluminum alloy target containing 80 ppm of manganese, to avoid strong self-absorption of Mn I lines.…”
Section: Determination Of Stark Broadening Coefficientsmentioning
confidence: 99%
“…The long laser plasma was observed in the side-on mode using the optical configuration described earlier (Popov et al 2016). Radiation of the second harmonics (532 nm, beam diameter = 6 mm, 8 ns, 82 mJ/pulse) of the Q-switched Nd:YAG laser (model LS-2134UTF, LOTIS TII, Belarus) was focused on the surface of magnesium alloy by a glass cylindrical lens (f = 500 mm).…”
Section: Set-up Descriptionmentioning
confidence: 99%
“…We have considered the influence of Doppler, pressure, resonance, and Van der Waals broadening mechanisms on the widths of Cu I lines. Calculation methodology is described elsewhere (Popov et al 2016;Konjević 1999); Table 3 lists widths calculated for Cu lines, and broadening of Mg and Al lines due to these effects may be considered negligible (Popov et al 2016). Generally, the widths listed in Table 3 were an order or two of magnitude lower than observed ones (up to hundreds of pm, see also Section 3.3), that we could neglect the influence of above mentioned mechanisms with the exception of Doppler broadening for copper line at 5105.54 Å at long delays.…”
Section: Estimation Of Line Widths Due To Different Broadening Mechan...mentioning
confidence: 99%
See 1 more Smart Citation
“…Анализ поверхности образцов перед проведением спектрального анализа выполнен в работах [2][3]. Исследование различных состояний информативного источника -электрической, лазерной и газовой плазмы, при проведении спектрального анализа и микроанализа представлено в работах [4][5][6][7].…”
unclassified