2015
DOI: 10.1016/j.icheatmasstransfer.2015.05.020
|View full text |Cite
|
Sign up to set email alerts
|

Experimental measurements and theoretical prediction for the volumetric heat transfer coefficient of a three-phase direct contact condenser

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
8
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 24 publications
(8 citation statements)
references
References 27 publications
(30 reference statements)
0
8
0
Order By: Relevance
“…Recently, Mahood and co-authors [9,[24][25][26][27][28][29] investigated theoretically and experimentally [24][25][26][27][28] the various characteristics of thermal performance of the three-phase direct contact condenser. The thermal efficiency and the capital cost of the three-phase direct contact condenser have been recently researched [9].…”
Section: Continuous Phase Inletmentioning
confidence: 99%
See 1 more Smart Citation
“…Recently, Mahood and co-authors [9,[24][25][26][27][28][29] investigated theoretically and experimentally [24][25][26][27][28] the various characteristics of thermal performance of the three-phase direct contact condenser. The thermal efficiency and the capital cost of the three-phase direct contact condenser have been recently researched [9].…”
Section: Continuous Phase Inletmentioning
confidence: 99%
“…The results showed for both cases that the mass flow rate ratio and the holdup fraction have a significant effect on the condenser outlet temperature. Also, the volumetric heat transfer coefficient in the condenser has studied experimentally for both steady-state and transient operation modes [26,27]…”
Section: Continuous Phase Inletmentioning
confidence: 99%
“…In addition, the temperature and pressure of the vapour pentane were measured before injection into the test section of the condenser. This technique is described in more detail elsewhere [30] and was used in previous studies [24][25][26][27][28]. The pentane was injected at a pressure of 0.…”
Section: Experimental Setup and Proceduresmentioning
confidence: 99%
“…They exploited previous models of the condensation of a single two-phase bubble in an immiscible liquid. Recently, Mahood et al investigated the three-phase direct contact condenser theoretically [21] and experimentally [24][25][26][27][28][29]. These studies investigated various characteristics of the thermal performance of a lab.-scale direct contact condenser during both transient and steady state operation.…”
mentioning
confidence: 99%
See 1 more Smart Citation