2015
DOI: 10.1617/s11527-015-0760-x
|View full text |Cite
|
Sign up to set email alerts
|

Experimental investigations of sandwich panels using high performance concrete thin plates exposed to fire

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
3
0
2

Year Published

2018
2018
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 13 publications
(10 citation statements)
references
References 17 publications
0
3
0
2
Order By: Relevance
“…Very importantly, the authors observed that the insulation stability was maintained only for non-load bearing walls and not for load-bearing walls. Hulin et al [23] found that loss of bonding action occurred at the interface due to differential thermal expansion. Huang et al [24] found that the axial load capacity decreased by 88.5 % after exposure to one-side fire exposure for 4-hour.…”
Section: Truss Shear Section X-xmentioning
confidence: 99%
“…Very importantly, the authors observed that the insulation stability was maintained only for non-load bearing walls and not for load-bearing walls. Hulin et al [23] found that loss of bonding action occurred at the interface due to differential thermal expansion. Huang et al [24] found that the axial load capacity decreased by 88.5 % after exposure to one-side fire exposure for 4-hour.…”
Section: Truss Shear Section X-xmentioning
confidence: 99%
“…İnce bir film ile ortotrop kaplama ara yüzeyi üzerindeki çatlak, düzgün ısı akışı altında analiz edilmiştir [9]. Yüksek performanslı beton kullanılarak üretilmiş ince plaklar ile imal edilen yangına maruz sandviç paneller, deneysel yöntemle çalışılmıştır [10]. Kırılma mekaniğinin ve termoelastisitenin farklı problemleri teknik literatürde geniş bir biçimde ele alınmaktadır.…”
Section: Gi̇ri̇ş (Inroduction)unclassified
“…Burada seçilen kusur türü literatürde tanımlanmış ve gerçek yapıda ortaya çıktığı tespit edilen kusur türlerinden biri olarak seçilmiştir. 10.17341/gazimmfd.460504 Anahtar Kelimeler: Kompozit levhalar, termal gerilme analizi, gerilme yığılma faktörü, sonlu eleman analizi, Nükleer reaktörler…”
unclassified
“…The authors conclude that for wellbalanced composite action, it is necessary to use the least amount of material in the plate connectors and an increased amount of bending capacity of the outer panel to avoid a significant drop in the load after the peak load. At the same line, Hulin et al [6] presents an experimental campaign at elevated temperatures for panels stiffened by structural ribs, insulation layers, and steel shear connectors. The results highlighted insulation shear failure from differential thermal expansion at the interface with concrete, where the shear connectors induced stress concentrations, leading to local failure.…”
Section: Introductionmentioning