2017
DOI: 10.1016/j.ijrefrig.2017.06.013
|View full text |Cite
|
Sign up to set email alerts
|

Experimental investigation on the performance of a transcritical CO 2 heat pump with multi-ejector expansion system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
26
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 50 publications
(27 citation statements)
references
References 16 publications
0
26
0
1
Order By: Relevance
“…The acronym EERC refers to refrigeration, but also to air-conditioning applications and heating. Depending on the working fluid, two types of EERC cycles are reported in the published literature: subcritical cycles [30,80] and transcritical CO 2 cycle [48,81]. The performances of the transcritical CO 2 cycles are generally superior to the other refrigerants.…”
Section: Applications Potential Of the Two-phase Ejectormentioning
confidence: 99%
See 1 more Smart Citation
“…The acronym EERC refers to refrigeration, but also to air-conditioning applications and heating. Depending on the working fluid, two types of EERC cycles are reported in the published literature: subcritical cycles [30,80] and transcritical CO 2 cycle [48,81]. The performances of the transcritical CO 2 cycles are generally superior to the other refrigerants.…”
Section: Applications Potential Of the Two-phase Ejectormentioning
confidence: 99%
“…The multi-ejector approach used by Hafner et al [173] was later employed by Boccardi et al [81] to conduct experiments on an air-to-water CO 2 heat pump for space heating under partial and full-load conditions. The authors evaluated individual components and overall heat pump performance, varied the ejector area ratio and the compressor frequency to adjust to ambient conditions from −15 to 12 • C. Optimal COP was possible by varying the ejector area, regulated to match with the pressures at the inlet and outlet of the compressor.…”
Section: Eerc Experimental Studiesmentioning
confidence: 99%
“…Typical operational strategies of such systems are full storage and partial storage strategies, as shown in Figure 1 [31]. Boccardi et al [20], instead, evaluate the performance improvement due to an ejector in a HVAC system working with CO₂ as refrigerant. The optimal configuration of the system is determined.…”
Section: Energy Storagementioning
confidence: 99%
“…Boccardi et al [20], instead, evaluate the performance improvement due to an ejector in a HVAC system working with CO 2 as refrigerant. The optimal configuration of the system is determined.…”
mentioning
confidence: 99%
“…Studies on implementation of the ejectors with converging-diverging nozzles in refrigeration, airconditioning and heat pumps demonstrated significant improvement of the energy efficiency of the discussed systems [1][2][3]. As a result, a growing interest in studying an operation and design of the ejector in mentioned systems can be observed [4][5][6].…”
Section: Introductionmentioning
confidence: 99%