2017
DOI: 10.1080/13632469.2016.1264333
|View full text |Cite
|
Sign up to set email alerts
|

Experimental Investigation on Steel W-Shaped Folded Plate Dissipative Connectors for Horizontal Precast Concrete Cladding Panels

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
18
0

Year Published

2017
2017
2018
2018

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 26 publications
(18 citation statements)
references
References 15 publications
0
18
0
Order By: Relevance
“…FBD [29,30,34] and FPA [28,34] with plastic dissipation have been used. FBD [29,30,34] and FPA [28,34] with plastic dissipation have been used.…”
Section: Full-scale Prototype Test Programmentioning
confidence: 99%
“…FBD [29,30,34] and FPA [28,34] with plastic dissipation have been used. FBD [29,30,34] and FPA [28,34] with plastic dissipation have been used.…”
Section: Full-scale Prototype Test Programmentioning
confidence: 99%
“…The panel‐to‐column plasticity‐based folded plate angle (FPA) device consists of a steel plate folded at right‐angle along three lines to get a W‐shaped profile, as shown in Figure for the tested connector . The longer internal plate segment is parallel to the panel side, and the shorter is parallel to the column surface.…”
Section: Experimental Programmentioning
confidence: 99%
“…The feasibility of each of the proposed design solutions has been investigated within the SAFECLADDING research project supported by a grant of the European Commission as part of the program FP7‐SME‐2012 . This research activity included solutions for existing and new precast structures with isostatic, integrated, and dissipative connection systems of the cladding panels . A description of the investigated solutions for each arrangement concerning both vertical and horizontal panels is available in Refs.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The various hysteretic shapes are reported in Figure 4 (1 example case for every structural type). Details on the geometrical/mechanical properties of the specimens are not presented in this paper for the sake of brevity, while exhaustive information can be found in the above‐cited referenced papers . The corresponding EVD curves shown in Figure 5 (1 example case for every structural type) are evaluated based on the EVD vectors associated to approaches (i) and (ii).…”
Section: Evaluation Of the Equivalent Viscous Damping Curves From Cycmentioning
confidence: 99%