Abstract:In this article, the behavior of heat and mass transfer relation during khoa making has been investigated. Various indoor experiments have been performed for simulation of developed thermal model for maximum evaporation during heating of milk. The data obtained from experimentation have been used to determine values of constant “C” and exponent “n” by simple regression analysis. Based on the values of “C” and “n,” convective and evaporative heat transfer coefficients for milk were determined. It was observed t… Show more
“…The evaporative heat transfer coefficients were observed to decrease 129.23% for the given range of heat inputs. The evaporative heat transfer coefficients obtained for sensible heating of milk in a stainless steel pot were compared with the values reported by Kumar et al, [12] for sensible heating of milk in an aluminum pot (Figure 2). It can be seen that the evaporative heat transfer coefficients during sensible heating of milk in a stainless steel pot follows the same trend as reported for the case of an aluminum pot.…”
Section: Resultsmentioning
confidence: 81%
“…The heating of milk during khoa making involves sensible heating and boiling convection heat transfer phases. Recently, Kumar et al., [12,13] experimentally evaluated the convective heat transfer coefficients during sensible heating of milk in aluminum [12] and stainless steel pots [13] [12,13]. The present research work may be helpful in designing an evaporator for khoa production.…”
Section: Introductionmentioning
confidence: 87%
“…The evaporative heat transfer coefficient (h e ) was calculated from Equation (1) which is given as [12,14]: The data obtained from experimentation were used to determine the values of the convective heat transfer coefficients. The details of the convective heat transfer coefficient values used for determining the evaporative heat transfer coefficients are given elsewhere [13].…”
Section: Computation Proceduresmentioning
confidence: 99%
“…The different physical properties of humid air, such as specific heat (C v ), thermal conductivity (K v ), density (ρ v ), viscosity (μ v ), and and partial vapor pressure, P(T) were determined by using following expressions [12,13] …”
“…The evaporative heat transfer coefficients were observed to decrease 129.23% for the given range of heat inputs. The evaporative heat transfer coefficients obtained for sensible heating of milk in a stainless steel pot were compared with the values reported by Kumar et al, [12] for sensible heating of milk in an aluminum pot (Figure 2). It can be seen that the evaporative heat transfer coefficients during sensible heating of milk in a stainless steel pot follows the same trend as reported for the case of an aluminum pot.…”
Section: Resultsmentioning
confidence: 81%
“…The heating of milk during khoa making involves sensible heating and boiling convection heat transfer phases. Recently, Kumar et al., [12,13] experimentally evaluated the convective heat transfer coefficients during sensible heating of milk in aluminum [12] and stainless steel pots [13] [12,13]. The present research work may be helpful in designing an evaporator for khoa production.…”
Section: Introductionmentioning
confidence: 87%
“…The evaporative heat transfer coefficient (h e ) was calculated from Equation (1) which is given as [12,14]: The data obtained from experimentation were used to determine the values of the convective heat transfer coefficients. The details of the convective heat transfer coefficient values used for determining the evaporative heat transfer coefficients are given elsewhere [13].…”
Section: Computation Proceduresmentioning
confidence: 99%
“…The different physical properties of humid air, such as specific heat (C v ), thermal conductivity (K v ), density (ρ v ), viscosity (μ v ), and and partial vapor pressure, P(T) were determined by using following expressions [12,13] …”
This research paper reports the results for convective heat transfer coefficient and nucleate boiling heat flux for pool boiling of milk during khoa making. Various indoor experiments were conducted for different heat flux inputs varying from 9638.55 to 14457.83 W/m 2 . Experimental data obtained for pool boiling of milk were analyzed by using the Rohsenow correlation with the help of simple linear regression analysis. The convective heat transfer coefficients were estimated in the range of 334.48 to 837.78 W/m 2 °C for the given heat inputs. The results for heat flux were found to be varying from 3344.8 to 8377.8 W/m 2 at 10 °C excess temperature of the aluminum pot surface above the saturation temperature of the milk. The experimental errors in terms of percent uncertainty were also calculated.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.