2017
DOI: 10.1016/j.ijrefrig.2017.01.010
|View full text |Cite
|
Sign up to set email alerts
|

Experimental investigation on heating performance of gas-injected scroll compressor using R32, R1234yf and their 20wt%/80wt% mixture under low ambient temperature

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 43 publications
(9 citation statements)
references
References 25 publications
0
9
0
Order By: Relevance
“…To ensure that the heating performance of the system is relatively high under the condition of low temperature, there are two key parameters for the system: the optimal location of the vapor injection inlets and the most suitable vapor injection pressure, both the two parameters were derived from experiment and calculation suggested by Xu et al [10]. Equation (1) was used to calculate the most suitable vapor injection pressure.…”
Section: Vapor Injection Heat Pump System (Vi System)mentioning
confidence: 99%
See 1 more Smart Citation
“…To ensure that the heating performance of the system is relatively high under the condition of low temperature, there are two key parameters for the system: the optimal location of the vapor injection inlets and the most suitable vapor injection pressure, both the two parameters were derived from experiment and calculation suggested by Xu et al [10]. Equation (1) was used to calculate the most suitable vapor injection pressure.…”
Section: Vapor Injection Heat Pump System (Vi System)mentioning
confidence: 99%
“…They stated that a reduction in the cooling capacity of 6% to 13% approximately was noted using R1234yf instead of R134a. Xu et al [10] developed an integrated gas-injected scroll compressor heat pump system using R1234yf, R32 and its binary mixtures as a working fluid, and the results showed that a R1234yf/R32 mixture can run at an evaporating temperature of −20 °C, and it has the highest heating COP value between R1234yf and R32.…”
Section: Introductionmentioning
confidence: 99%
“…R404A is an azeotropic blend of 143a/125/134a with zero ODP, and is nonflammable, nontoxic, and operates under low pressure, but has a GWP of 3922 [52]. R407A [53], R407F [54], R407H [55], R410A [56], R442A [57], R448A [58], R449A [59], R452A [60], R453A [57], and R463A [50] were developed to be retrofitted to replace R404A, and are mixed with HCs, HFOs, R134A, and R32. This is similar to the refrigerant that was developed for R22 and R134A but does not include R463A, which is being presented as a refrigerant for comparative purposes in this research as it is composed of R744 (carbon dioxide), which is a natural refrigerant similar to R445A [61] and R455A [62].…”
Section: Introductionmentioning
confidence: 99%
“…In these studies, the improvements in COP, capacity, and the extension of the work map of the systems are quantified (Ma et al, 2003;Ma and Chai, 2004;Ma and Zhao, 2008;Wang et al, 2009b;Navarro et al, 2013). Other studies have focused on the control and optimization of the system (Wang et al, 2009a and2009c;Xu et al, 2011b;Cho et al, 2012;Roh and Kim, 2011), and the use of different refrigerants in vapor-injection cycles (Feng et al, 2009;Xu et al, 2013aXu et al, , 2013bXu et al, and 2017. Moreover, the SCVI characterization methodologies have addressed by Winandy Nevertheless, scroll compressors have a fixed built-in volume ratio, which is determined by the scroll geometry.…”
Section: Introductionmentioning
confidence: 99%