Experimental Investigation on FRA Diagnosis of Transformer Faults

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
15
0

Year Published

2012
2012
2017
2017

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 18 publications
(15 citation statements)
references
References 1 publication
0
15
0
Order By: Relevance
“…Figure 3 shows an example of the simulation circuit. The winding was simulated by an RLC ladder circuit designed for surge simulation [4], and the analysis was performed with the ATP-EMTP frequency scan function.…”
Section: Principles Of Framentioning
confidence: 99%
See 2 more Smart Citations
“…Figure 3 shows an example of the simulation circuit. The winding was simulated by an RLC ladder circuit designed for surge simulation [4], and the analysis was performed with the ATP-EMTP frequency scan function.…”
Section: Principles Of Framentioning
confidence: 99%
“…If the ratio of the fr values in air and in the oil-immersed state is separated into the insulating oil/air ratio (fr A ), the interwinding ratio (fr B ), and the intersection ratio (fr C ), we can write Eqs. (2) to (4). The interwinding and intersection dielectric constants are calculated values with the configuration of the solid insulator in the transformer taken into account:…”
Section: Case 1 (Effect Of Presence Of Insulating Oil)mentioning
confidence: 99%
See 1 more Smart Citation
“…Therefore, it is important to detect such deformation and displacement. Frequency response analysis (FRA) [1][2][3][4][5][6] is capable of detecting such the deformation and displacement of windings, with high sensitivity. In FRA, transfer functions are measured in the frequency range from several tens of Hz to several MHz.…”
Section: Introductionmentioning
confidence: 99%
“…Among them, in late years, FRA attracts attention as a new diagnostic technique for diagnosing deformation and poor contact from outside the transformer. There are many reports about FRA available on the accuracy and techniques of diagnosis [4][5] [6], and a report was published in April, 2008 by CIGRE WG SC A2.26 on the diagnosis of transformers using FRA measurements [7]. Further, IEC standardization is being planned, and a guideline will be presented for measurement techniques and diagnostic techniques.…”
Section: Introductionmentioning
confidence: 99%