Abstract::In order to investigate the compression behavior of double lipped channel cold-formed thin-wall steel column used in Box housing, a total of 12 columns with three different lengths(3000mm,2556mm,2000mm, respectively)and two different thickness(3mm, 4mm )were tested to investigate the ultimate load-carrying capacity and deformation behavior of cold-formed steel. It is found that the thickness has an obvious effect on compression ultimate load-carrying capacity, while the length does not have much influence. Th… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.