2016
DOI: 10.1016/j.apenergy.2016.02.140
|View full text |Cite
|
Sign up to set email alerts
|

Experimental investigation of the thermal and electrical performance of the heat pipe BIPV/T system with metal wires

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
3

Relationship

1
8

Authors

Journals

citations
Cited by 34 publications
(8 citation statements)
references
References 25 publications
0
8
0
Order By: Relevance
“…Comparison of the testing results with Wang et al 19 Wang et al 19 designed the metal-wires-based-BIPV/T system with the conventional finned heat pipes as shown in Figure 20. The only difference between the two systems was that the micro-channel flat-plate heat pipes of the proposed system replaced the conventional heat pipes of the metal-wires-based-BIPV/T system.…”
Section: Performance Comparison With the Previous Research Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Comparison of the testing results with Wang et al 19 Wang et al 19 designed the metal-wires-based-BIPV/T system with the conventional finned heat pipes as shown in Figure 20. The only difference between the two systems was that the micro-channel flat-plate heat pipes of the proposed system replaced the conventional heat pipes of the metal-wires-based-BIPV/T system.…”
Section: Performance Comparison With the Previous Research Resultsmentioning
confidence: 99%
“…Moradgholi et al 18 investigated the performance of the thermosiphon-type heat-pipe PV/T system with different working fluids in both spring and summer seasons. Wang et al 19 investigated the conventional finned heat pipes BIPV/T system with the metal wires filling into the space between the PV panel and heat pipes, and found that the maximum thermal efficiency and electrical efficiency of the system were at 44.04% and 7.9%, respectively.…”
Section: Introductionmentioning
confidence: 99%
“…The PV panel is modelled using Type 94 of TRNSYS software, recommended in modelling monocrystalline or polycrystalline silicon modules. For a more realistic analysis, the four parameters model is used [13,14], which takes into account both series and shunt resistances, R s and R sh .…”
Section: Numerical Modellingmentioning
confidence: 99%
“…Wang et al. 104 proposed metal wires for such systems to enhance the electrical efficiency. The system thermal efficiency was measured for different solar radiations and water flow rate by simulation.…”
Section: Application For Building Façade and With Other Technologiesmentioning
confidence: 99%