Experimental Investigation of Rotor-Stator Interaction in a Centrifugal Pump With Several Vaned Diffusers

Abstract: This paper describes an experimental investigation of rotor-stator interaction in a centrifugal pump with several vaned diffusers. Steady and unsteady diffuser vane pressure measurements were made for a two-dimensional test impeller. Unsteady impeller blade pressure measurements were made for a second two-dimensional impeller with blade number and blade geometry identical to the two-dimensional impeller used for the diffuser vane pressure measurements. The experiments were conducted for different flow coeffici… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
48
0
2

Year Published

1998
1998
2019
2019

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 133 publications
(54 citation statements)
references
References 7 publications
1
48
0
2
Order By: Relevance
“…One of the flow phenomena that cause this unsteady hydraulic force is the interaction between a rotating blade and a stator vane [3][4][5][6]. It causes the unsteady hydraulic forces in the blade passing frequency and its higher harmonic frequencies.…”
Section: Introductionmentioning
confidence: 99%
“…One of the flow phenomena that cause this unsteady hydraulic force is the interaction between a rotating blade and a stator vane [3][4][5][6]. It causes the unsteady hydraulic forces in the blade passing frequency and its higher harmonic frequencies.…”
Section: Introductionmentioning
confidence: 99%
“…Pressure pulsation coefficient is defined as h à = p=(r 3 g 3 U The model pump frequency domain of the original blade is somewhat similar to other analyses for a pump with a diffuser. [23][24][25] The frequency domain of the staggered blade is somewhat similar to some doublesuction pumps. 26 The frequency domain analysis and comparison showed the characteristics of pressure pulsation.…”
Section: Unsteady Cfd Results and Analysismentioning
confidence: 93%
“…Dans ce but, de nombreux travaux expérimentaux [l, 2,3] et numériques [4,5,6,7,8] ont été réalisés. Notons cependant que la plupart des travaux numériques considèrent séparément l'écoulement dans la partie tournante et dans la partie fixe [5,6] ou bien un écoulement potentiel ou quasi statique [4,9].…”