2020
DOI: 10.1016/j.ijheatmasstransfer.2020.120359
|View full text |Cite
|
Sign up to set email alerts
|

Experimental investigation of heat and mass transfer characteristics in direct contact exchanger

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(4 citation statements)
references
References 22 publications
0
4
0
Order By: Relevance
“…Several times less moisture evaporates from the surface of the droplets in the airflow (the evaporation share from the surface of the droplets is usually less than 20%) than from the liquid layer surface on the blades and compressor housing [50]. (4) Mechanical losses due to the drop acceleration of the flow and rotating blades' deceleration of the impellers drop by their repeated deposition and surface failure of the blades and housing, as well as friction, liquid layer on the blades' surface, and compressor housing [22,51]. As a result, the stage's internal efficiency and the compressor are reduced [52].…”
Section: Literature Reviewmentioning
confidence: 99%
See 1 more Smart Citation
“…Several times less moisture evaporates from the surface of the droplets in the airflow (the evaporation share from the surface of the droplets is usually less than 20%) than from the liquid layer surface on the blades and compressor housing [50]. (4) Mechanical losses due to the drop acceleration of the flow and rotating blades' deceleration of the impellers drop by their repeated deposition and surface failure of the blades and housing, as well as friction, liquid layer on the blades' surface, and compressor housing [22,51]. As a result, the stage's internal efficiency and the compressor are reduced [52].…”
Section: Literature Reviewmentioning
confidence: 99%
“…Another effective spraying method for a highly dispersed flow is using a liquid that is superheated relative to the saturation temperature. At the same time, the spray efficiency is ensured by the instantaneous evaporation process and, as a result, the liquid droplet's effective crushing [51,56].…”
Section: Literature Reviewmentioning
confidence: 99%
“…Wijeysundera et al [6] developed an ice slurry generation system with DCHT between water and the coolant (Fluorinert FC-84) and found that the efficiency of ice fabrication increased by about 40 percent. Barabash et al [7] introduced the DCHT technology in cooling towers and for cooling gas flow; they declared that the presence of DCHT can obviously improve the heat transfer efficiency. Mahood et al [2] investigated the heat transfer efficiency, and hence the cost of a three-phase direct-contact condenser, and found that its investment expenses were 30 times lower than those of the corresponding surface condenser (shell-and-tube condenser).…”
Section: Introductionmentioning
confidence: 99%
“…Tungsten-copper and iron based chromel alloy were effectively utilized for temperature applications 3 . In direct contact type heat exchanger, chromel thermocouple was used to find the water temperature at the bottom of heat exchanger to withstand corrosion 4 . Tantalum carbide (TaCx) was used to enrich the carbon content of the material and also to strengthen the interfacial alloying elements through different compositions.…”
Section: Introductionmentioning
confidence: 99%