2019
DOI: 10.1016/j.enbuild.2019.109449
|View full text |Cite
|
Sign up to set email alerts
|

Experimental investigation of energy and exergy performance of a direct evaporative cooler using a new pad type

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
37
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 63 publications
(37 citation statements)
references
References 32 publications
0
37
0
Order By: Relevance
“…Al-Mogbel et al [30] distinguish "Effectiveness of DEC cooler" from "Effectiveness of IEC cooler". Some authors [10,[31][32][33][34][35][36] define the "cooling efficiency" clarifying that it is the saturation efficiency/effectiveness. Al-Badri and Al-Waaly [37] specify that "the effectiveness of DEC was expressed by the saturation efficiency".…”
Section: Abbreviationsmentioning
confidence: 99%
See 1 more Smart Citation
“…Al-Mogbel et al [30] distinguish "Effectiveness of DEC cooler" from "Effectiveness of IEC cooler". Some authors [10,[31][32][33][34][35][36] define the "cooling efficiency" clarifying that it is the saturation efficiency/effectiveness. Al-Badri and Al-Waaly [37] specify that "the effectiveness of DEC was expressed by the saturation efficiency".…”
Section: Abbreviationsmentioning
confidence: 99%
“…Experimental results from Camargo et al [61] show that the saturation effectiveness improves for higher DBT, when "more cooling is necessary to propitiate thermal comfort"; however, no information is given about the air humidity. Similarly, Nada et al [31,42] observe that larger inlet DBT result into also larger humidity increase and consequent temperature drop, cooling capacity and coefficient of performance, as well as into an increase in the saturation effectiveness, but do not provide information on the inlet air humidity during the tests. Sheng and Nnanna [63] also provide experimental results of the saturation effectiveness increase with the DBT, though observe the relevance of air humidity and propose the study of the saturation effectiveness variation in terms of the "humidity ratio increase" (in g/kg).…”
Section: Inlet Air Psychrometric Conditionsmentioning
confidence: 99%
“…It makes use of additional air source that is heated before it reaches the cooling pads. This generates cooler air [3]. The current topic discusses direct evaporative cooling mechanism and coconut coir as the cooling pad material selected in this study.…”
Section: Introductionmentioning
confidence: 99%
“…Marmouch et al 9 studied the characteristics of a packing bed to be used in the cooling tower of the HDH fresh water production system. Recently, Nada et al 10 evaluated the performance of air humidification in a new packing bed at different air and water flow rates and temperatures and different thicknesses of the packing bed to find the parameters that give optimum performance. Zhani and Ben Bacha 11 experimentally studied the variation of relative humidity (RH) in the air heater and humidifier of the HDH system.…”
Section: Introductionmentioning
confidence: 99%