2010
DOI: 10.1016/j.applthermaleng.2009.09.012
|View full text |Cite
|
Sign up to set email alerts
|

Experimental investigation of effective parameters and correlation of geyser boiling in a two-phase closed thermosyphon

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
32
0
2

Year Published

2010
2010
2020
2020

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 98 publications
(36 citation statements)
references
References 5 publications
2
32
0
2
Order By: Relevance
“…The study results obtained correlate well with the theoretical and experimental data [7]. The results of an experimental study of methanol boiling in a closed biphasic thermosyphon are given in [8]. We have studied the thermosyphon with a height of 1000 mm and diameter of steam channel of 25mm.…”
Section: Introductionsupporting
confidence: 71%
“…The study results obtained correlate well with the theoretical and experimental data [7]. The results of an experimental study of methanol boiling in a closed biphasic thermosyphon are given in [8]. We have studied the thermosyphon with a height of 1000 mm and diameter of steam channel of 25mm.…”
Section: Introductionsupporting
confidence: 71%
“…Figure 6 presents a schematic of the geyser boiling phenomenon [17]. When the liquid pool in the evaporator section is gradually heated until it becomes superheated, a vapour bubble grows and expands to the size of the inner diameter of the thermosyphon.…”
Section: Geyser Boilingmentioning
confidence: 99%
“…Khazaee et al [17] experimentally investigated the geyser boiling phenomenon in a two-phase closed thermosyphon for water as a working fluid. They investigated the effects of filling ratio, aspect ratio, heat input and coolant mass flow rate on geyser boiling by testing the period of the geyser boiling.…”
Section: Introductionmentioning
confidence: 99%
“…This last fact might explain why Ong and Haider-E-Alahi [6] and Abou-Ziyan et al [7], having different evaporator, riser and condenser lengths, found different optimal filling ratios. Khazaee et al [9] have investigated the influence of filling on the behaviour of geyser boiling in a two-phase closed thermosyphon and discovered that by increasing the filling, the period of geyser boiling and the intensity of temperature oscillation increased, but when the filling becomes less than 30%, the geyser boiling disappears.…”
Section: Introductionmentioning
confidence: 99%