2018
DOI: 10.1016/j.applthermaleng.2018.05.050
|View full text |Cite
|
Sign up to set email alerts
|

Experimental investigation and dynamic modeling of a triple-glazed exhaust air window with built-in venetian blinds in the cooling season

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
13
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
1
1

Relationship

1
6

Authors

Journals

citations
Cited by 31 publications
(15 citation statements)
references
References 39 publications
0
13
0
Order By: Relevance
“…Other similar systems, yet more complex, involve triple-glazed windows dealing both with the heating and the cooling period, aiming at keeping high the internal pane's temperature on the heating mode, and cooling the external pane on the cooling mode, via the ventilation strategy followed [38]. A venetian blind addition could further enhance the systems' performance [39].…”
Section: Permeodynamic-parietodynamic Insulationmentioning
confidence: 99%
See 1 more Smart Citation
“…Other similar systems, yet more complex, involve triple-glazed windows dealing both with the heating and the cooling period, aiming at keeping high the internal pane's temperature on the heating mode, and cooling the external pane on the cooling mode, via the ventilation strategy followed [38]. A venetian blind addition could further enhance the systems' performance [39].…”
Section: Permeodynamic-parietodynamic Insulationmentioning
confidence: 99%
“…From the thermal diode assemblies described in the relevant paragraph, only the one operating with gravity for possible roof application might be sustainable for an existing building [25], as it requires no further mechanism or automation for its proper operation. Double skin facades [27][28], is already a common renovating technique, whereas the exhaust air windows [37]- [39], can be easily applied even to existing buildings, necessarily accompanied by the proper HVAC systems to assure their proper operation.…”
Section: Application Potentialsmentioning
confidence: 99%
“…The detailed information about the development of the zonal model for evaluating the thermal performance of the VEW can be found in our previous studies [4]. It should be noticed that the subsection number in vertical direction may directly affect the calculation accuracy as well as the computation time of the zonal model.…”
Section: Development Of Zonal Modelmentioning
confidence: 99%
“…The experiment setup, test sample, measurement facilities, and measured boundary conditions can be found in Ref. [4]. The comparison of the numerical modeling and experiment measurement is presented in Fig.…”
Section: Model Validationmentioning
confidence: 99%
See 1 more Smart Citation