2012
DOI: 10.1016/j.joen.2011.10.017
|View full text |Cite
|
Sign up to set email alerts
|

Experimental Evaluation on the Influence of Autoclave Sterilization on the Cyclic Fatigue of New Nickel-Titanium Rotary Instruments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
92
2
8

Year Published

2013
2013
2021
2021

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 95 publications
(111 citation statements)
references
References 35 publications
(36 reference statements)
5
92
2
8
Order By: Relevance
“…After shaping procedures were completed all the 40 used NiTi instruments were inspected under magnification (3x) to check any sign of plastic deformation or undwinding of flutes. All the instruments were then subjected to cyclic fatigue test using a testing device that was previously described (21)(22)(23)(24)(25)(26)(27). Briefly, all instruments were tested using the TFA motion powered by Elements motor (SybronEndo, Orange, CA, USA).…”
Section: Methodsmentioning
confidence: 99%
“…After shaping procedures were completed all the 40 used NiTi instruments were inspected under magnification (3x) to check any sign of plastic deformation or undwinding of flutes. All the instruments were then subjected to cyclic fatigue test using a testing device that was previously described (21)(22)(23)(24)(25)(26)(27). Briefly, all instruments were tested using the TFA motion powered by Elements motor (SybronEndo, Orange, CA, USA).…”
Section: Methodsmentioning
confidence: 99%
“…The study found that K4 prototype instruments showed a significant increase in the mean number of cycles to failure when compared with K3 instruments (1198 AE 279 vs 542 AE 81). Furthermore, the effect of autoclave sterilization on the cyclic fatigue resistance of K3XF was also evaluated by the same research group (86). The results showed that repeated cycles of autoclave sterilization do not seem to influence the cyclic fatigue resistance of K3, Mtwo, or Vortex NiTi instruments.…”
Section: R-phasementioning
confidence: 99%
“…30 Çalışmamızda kullandığımız bir diğer enstürman olan K3XF enstür-manı da, aynı R-Phase ısı ve soğutma protokolü ile üretilmesine rağmen, TFA enstürmanı gibi bükülme işlemi yerine tornada kesilme işlemiyle üretilmekte-dir. 31 TF enstürmanı trianguler üçgen kesite sahipken, K3XF enstürmanı, üçlü U şekilli çapraz kesite ve 3 adet radyal alana sahiptir. 32 Çalışmamızın sonucunda TFA enstürmanın K3XF enstrümanına göre preparasyon sonrası oluşan kök dentin dayanımın yüksek olmasını, enstürmanların sahip olduğu farklı çapraz kesit dizaynları ve üretim aşamasındaki burulma ve tornada kesilerek üretilmelerindeki farklılıklardan kaynaklanabileceğini düşünmekteyiz.…”
Section: Discussionunclassified