Experimental evaluation of some current injection-voltage reading patterns in electrical impedance tomography (EIT) and comparison to simulation results - Case study: Large scales

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 23 publications
0
6
0
Order By: Relevance
“…In another phantom study, configurations of even values of electrode skipping patterns were found better than those of odd values (Luppi Silva et al 2017). Recently, Tarabi et al recommended that in industrial application of EIT for conductive carrier-phases and in large domains, the patterns of opposite current injection and adjacent voltage measurement should be used because the highest correlation of image reconstruction of simulation with experimental data could be obtained with this pattern (Tarabi et al 2022). Russo et al argued that arrangement of the adjacent current injection and the opposite voltage measurement was preferable in the optimization of EIT-based stretchable sensors (Russo et al 2017).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In another phantom study, configurations of even values of electrode skipping patterns were found better than those of odd values (Luppi Silva et al 2017). Recently, Tarabi et al recommended that in industrial application of EIT for conductive carrier-phases and in large domains, the patterns of opposite current injection and adjacent voltage measurement should be used because the highest correlation of image reconstruction of simulation with experimental data could be obtained with this pattern (Tarabi et al 2022). Russo et al argued that arrangement of the adjacent current injection and the opposite voltage measurement was preferable in the optimization of EIT-based stretchable sensors (Russo et al 2017).…”
Section: Discussionmentioning
confidence: 99%
“…Several groups have studied the influence of current injection on EIT reconstruction (e.g. Seagar et al 1987, Xu et al 2008, Zhang et al 2010, Adler et al 2011, Bera and Nagaraju 2012, Luppi Silva et al 2017, Russo et al 2017, Tarabi et al 2022. Most of the previous studies employed simulation or phantoms with homogeneous impedance distribution, which is far different from the actual human chest with highly inhomogeneous impedance distribution.…”
Section: Introductionmentioning
confidence: 99%
“…Considering the electrode placement shown in figure 2, the adjacent pattern is used for injection and measurement, the BIM current source is initially connected to the electrodes 1 and 2, and the voltages are measured across each pair of consecutive electrodes, provided they are different from those used for injection [35].…”
Section: Injection and Measurement Patternsmentioning
confidence: 99%
“…12 In addition, image reconstruction is also a hot topic which refers to calculation of internal conductivity distribution from boundary voltage measurements. 13,14 However, such a process is an inherently nonlinear and seriously ill-posed problem. 15 The nonlinearity is caused by soft field characteristic of the electric field which makes the distribution of sensitive field easily affected by medium distribution.…”
Section: Introductionmentioning
confidence: 99%
“…In EIT, a variety of studies have been conducted, such as quantization error and electrode position errors in the modeling 12 . In addition, image reconstruction is also a hot topic which refers to calculation of internal conductivity distribution from boundary voltage measurements 13 , 14 . However, such a process is an inherently nonlinear and seriously ill-posed problem 15 .…”
Section: Introductionmentioning