1968
DOI: 10.13182/nse68-a19537
|View full text |Cite
|
Sign up to set email alerts
|

Experimental Evaluation of Minima in the Total Neutron Cross Sections of Several Shielding Materials

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

1971
1971
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…However the use of MCNP makes it easier to imply the detector resolution, to calculate the contribution of collided neutrons, sensitivity etc. Propagation of the C/E underestimation observed for the 60" O-broomstick neutron transmission with ENDF/B-VIII.0 data to the 16 O(n,↵) cross section suggests to decrease these data by 10 -15% between 5.5 and 8.0 MeV. This is confirmed by the thick target neutron yield induced by ↵-particles with energies up to 5 -6 MeV in carbon.…”
Section: Ornl Oxygen Broomstickmentioning
confidence: 71%
See 2 more Smart Citations
“…However the use of MCNP makes it easier to imply the detector resolution, to calculate the contribution of collided neutrons, sensitivity etc. Propagation of the C/E underestimation observed for the 60" O-broomstick neutron transmission with ENDF/B-VIII.0 data to the 16 O(n,↵) cross section suggests to decrease these data by 10 -15% between 5.5 and 8.0 MeV. This is confirmed by the thick target neutron yield induced by ↵-particles with energies up to 5 -6 MeV in carbon.…”
Section: Ornl Oxygen Broomstickmentioning
confidence: 71%
“…A rare example of a pure oxygen benchmark is the existing entry NEA-1517/59 (SDT2) of the SINBAD database [3]. This comprises the results of measurement of the neutron transmission spectra through the liquid oxygen broomstick of the large length 60" (152.4 cm) [16]. The experiment was performed in 1965 at the Tower Shielding Facility located in ORNL and was designed to measure the neutron total cross sections in the range of 1.9-8.6 MeV, Fig.…”
Section: Ornl Oxygen Broomstickmentioning
confidence: 99%
See 1 more Smart Citation
“…As an example of this process, within the last year analysis of an iron benchmark experiment [6] led to the remeasurements of the iron total cross section between 20 and 300 keV revealing factors of 2 errors in the interference minima [4] and within the last few months reanalysis of the iron broomstick experiment [7,8] [7] and sodium [18] are being fully documented. In all cases there is a clear need for sensitivity analyses when these experiments are used to evaluate uncertainties in a given design problem.…”
Section: Elements Of a Shielding Methodsmentioning
confidence: 99%
“…All of the calculations of the NE-213 spectra were smoothed with the resolution funct.ion of the spectrometer. 14 In general, undulations in the smoothed spect~a above 3 MeV are due to the coarse. group structure used in the calculations, i .…”
Section: Description Of the Experimentsmentioning
confidence: 99%