Experimental Devices Versus Hand-Sewn Anastomosis of the Aorta: A Systematic Review and Meta-Analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2021
2021
2021
2021

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 42 publications
0
2
0
Order By: Relevance
“…The ringed graft device was the most widely used; however, its application was finally challenged. Another review study [15] showed that although the device was designed to form automated ringed anastomosis on each side of the graft, a successful two-side ringed anastomosis was performed for only half of the patients. Several researchers have previously highlighted the difficulties during the placement of a ringed graft, such as mismatch between the ring diameter and aneurysm neck or the inability to insert the ring due to extensive calcification of the vessel, which make the device use significantly dependent on the anatomy of the patient.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The ringed graft device was the most widely used; however, its application was finally challenged. Another review study [15] showed that although the device was designed to form automated ringed anastomosis on each side of the graft, a successful two-side ringed anastomosis was performed for only half of the patients. Several researchers have previously highlighted the difficulties during the placement of a ringed graft, such as mismatch between the ring diameter and aneurysm neck or the inability to insert the ring due to extensive calcification of the vessel, which make the device use significantly dependent on the anatomy of the patient.…”
Section: Discussionmentioning
confidence: 99%
“…Several alternative methods have been suggested incorporating the use of ringed grafts, stents, staplers, couplers, or adhesives, however, none of them have successfully replaced the hand-sewn technique in everyday clinical practice. Previous research on the efficacy of such devices in end-to-end anastomosis of the aorta has shown that, although they offer a faster anastomosis and satisfactory short-term mortality rates, they are inferior in terms of tensile strength compared with the hand-sewn technique [14,15].…”
Section: Introductionmentioning