2021
DOI: 10.1016/j.applthermaleng.2021.116671
|View full text |Cite
|
Sign up to set email alerts
|

Experimental determination of the optimum intermediate and gas-cooler pressures of a commercial transcritical CO2 refrigeration plant with parallel compression

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
5
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 30 publications
(10 citation statements)
references
References 19 publications
1
5
0
1
Order By: Relevance
“…Nebot-Andrés et al have conducted an experimental study to investigate the vapour compression refrigeration system using two compression stages, and to determine the optimal operating situations. The authors have concluded that there is a correlation between the COP value and the intermediate pressure, and if it decreases or increases, the COP value decreases [11].…”
Section: Kim and Bullard Have Conducted An Experimental Study To Anal...mentioning
confidence: 99%
“…Nebot-Andrés et al have conducted an experimental study to investigate the vapour compression refrigeration system using two compression stages, and to determine the optimal operating situations. The authors have concluded that there is a correlation between the COP value and the intermediate pressure, and if it decreases or increases, the COP value decreases [11].…”
Section: Kim and Bullard Have Conducted An Experimental Study To Anal...mentioning
confidence: 99%
“…In order to evaluate the unavoidable exergy destruction of components in the system, further exergy analysis was carried out. The ratio exergy of refrigerants at each point of state can be defined as [20] : (12) where subscript j represents the exergy state points 1-15 in Figure 1, and 0 represents the reference state point of the system (T0 and P0). The reference state is generally set to the ambient temperature, the specific enthalpy and specific Entropy of refrigerant at = 298.15K and = 101.325kPa.…”
Section: Conventional Exergy Analysis Modelmentioning
confidence: 99%
“…It was found that the performance of the new cycle introduced after adjusting the different system parameters is 20-80% higher than that of the conventional cycle [11] . Nebot et al [12] sought a high performance refrigeration system to optimize the performance of the system in actual operation. The experiments validated the existence of the optimum intermediate pressure and the optimum pressure of the gas cooler in the novel transcritical CO2 refrigeration system.…”
Section: Introductionmentioning
confidence: 99%
“…The five controlled devices target values can be regulated steplessly within the adjustment range to obtain any experimentally required operating conditions. Laura Nebot-Andr´es et al 19 established the experimental CO 2 plant used to obtain optimal operating conditions at gas cooler exit temperatures of 27.5 °C, 32.5 °C and 37.5 °C and evaporation levels of −15.0 °C, −10.0 °C and −5.0 °C. In 19, the devices were regulated singly.…”
Section: Introductionmentioning
confidence: 99%