2014
DOI: 10.1016/j.ijhydene.2014.07.080
|View full text |Cite
|
Sign up to set email alerts
|

Experimental determination of parameters of multichannel hydrogen diffusion in solid probe

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0
1

Year Published

2015
2015
2020
2020

Publication Types

Select...
5
3
1

Relationship

3
6

Authors

Journals

citations
Cited by 32 publications
(12 citation statements)
references
References 16 publications
0
11
0
1
Order By: Relevance
“…Each peak in the curve is related to hydro gen traps of a certain kind and to a certain sample tem perature in the course of an analysis. Application of the procedure described in [11] makes it possible to approximate the extraction curve by using the multi channel diffusion model and determine the binding energy of hydrogen. The application of this proce dure is illustrated in the figure for sample D37.…”
Section: Determining the Content And Binding Energy Of Hydrogen In DImentioning
confidence: 99%
See 1 more Smart Citation
“…Each peak in the curve is related to hydro gen traps of a certain kind and to a certain sample tem perature in the course of an analysis. Application of the procedure described in [11] makes it possible to approximate the extraction curve by using the multi channel diffusion model and determine the binding energy of hydrogen. The application of this proce dure is illustrated in the figure for sample D37.…”
Section: Determining the Content And Binding Energy Of Hydrogen In DImentioning
confidence: 99%
“…In experiments with dia mond films on silicon substrates, the content of hydro gen was hundreds of times higher and, therefore, the flux of hydrogen from the substrate can be neglected. We calibrated the AV 1 hydrogen analyzer against the standard molecular hydrogen flow into vacuum [11]. The instrument was prepared in conformity with the requirements of GOST (State Standard) 21132.1-98.…”
mentioning
confidence: 99%
“…An industrial hydrogen analyser AV-1 (Electronic and Beam Technologies Ltd., St. Petersburg, Russia) was used with mass-spectrometric registration of the time dependence of hydrogen flux from samples heated in vacuum [21]. The analyser was calibrated on certified hydrogen-containing samples of an aluminium alloy with the error of the certified value of hydrogen concentration of 6%.…”
Section: Methodsmentioning
confidence: 99%
“…-1 ) от расстояния x (в мм) от геометрического центра образцов до линии излома: сплошная линия -образцы с поверхностным слоем; пунктирная -с удаленным слоем поверхности исходного образца толщиной 500 мкм Методики измерений описаны в [23,24]. Определение растворенного водорода про-водилось согласно стандарту [25].…”
Section: рис 1 образцы после механических испытанийunclassified