2003
DOI: 10.1097/01.brs.0000092217.34981.e1
|View full text |Cite
|
Sign up to set email alerts
|

Experimental Design of Total Disk Replacement—Experience with a Prospective Randomized Study of the SB Charitè

Abstract: This is the first study that shows improvement of functional outcome measures in a prospective randomized design treating primarily mechanical back pain and achieving comparable successful results to lumbar spinal stenosis decompression.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
23
0
4

Year Published

2005
2005
2016
2016

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 55 publications
(27 citation statements)
references
References 20 publications
0
23
0
4
Order By: Relevance
“…The device configuration is mostly a total replacement design from anterior transabdominal or retroperitoneal approach [6,8,11,14,23,37]. The representative metal on polymer artificial discs include SB Charite and ProDisc, in which polyethylene core is placed between two metal endplates with unconstrained or semi-constrained design and in macrophages at periprosthetic tissues with Bryan cervical disc replacement [1].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The device configuration is mostly a total replacement design from anterior transabdominal or retroperitoneal approach [6,8,11,14,23,37]. The representative metal on polymer artificial discs include SB Charite and ProDisc, in which polyethylene core is placed between two metal endplates with unconstrained or semi-constrained design and in macrophages at periprosthetic tissues with Bryan cervical disc replacement [1].…”
Section: Discussionmentioning
confidence: 99%
“…Recent artificial disc prostheses are classified into a metal on polymer [4,11,13,14,23,37], metal on metal [7,15,19], and exclusive polymer design [18,20,21,29,30,35,36]. The device configuration is mostly a total replacement design from anterior transabdominal or retroperitoneal approach [6,8,11,14,23,37].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The device was implanted into the discectomied space according to the manufacturer's specifications with fluoroscopy (15,16). The optimal position in the anteroposterior plane was at the midline, but it was 2 mm posterior to the midline on the lateral image.…”
Section: Fixation and Implantation In The Cadaveric Spinementioning
confidence: 99%
“…The device was implanted in the discectomy defect per manufacturer's specifications, and according to the previously reported surgical technique 30,32) . The midline of the spinal column was marked by placing a screw in the vertebral body above the index disc.…”
Section: Discectomy and Artificial Disc Implantationmentioning
confidence: 99%