2007 IEEE Nuclear Science Symposium Conference Record 2007
DOI: 10.1109/nssmic.2007.4436724
|View full text |Cite
|
Sign up to set email alerts
|

Experimental comparison of lesion detectability for four fully-3D PET reconstruction schemes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
39
1

Year Published

2010
2010
2021
2021

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 16 publications
(41 citation statements)
references
References 29 publications
1
39
1
Order By: Relevance
“…Kadrmas et al . (Kadrmas et al ., 2009a; Kadrmas et al ., 2009b) performed numeric channelized non-prewhitened (CNPW) (discussed below) as well as human observer studies of tumour detection using a multi-component whole-body phantom with realistic FDG uptake and including “shell-less” 68 Ge silicone gel lesions. Inclusion of RM led to statistically significant improvements in the context of localization ROC (LROC) analysis.…”
Section: Discussionmentioning
confidence: 99%
“…Kadrmas et al . (Kadrmas et al ., 2009a; Kadrmas et al ., 2009b) performed numeric channelized non-prewhitened (CNPW) (discussed below) as well as human observer studies of tumour detection using a multi-component whole-body phantom with realistic FDG uptake and including “shell-less” 68 Ge silicone gel lesions. Inclusion of RM led to statistically significant improvements in the context of localization ROC (LROC) analysis.…”
Section: Discussionmentioning
confidence: 99%
“…Additional details regarding the CNPW observer and its training and application to our experimental phantom data can be found in [58, 13, 17]. Of note, the observer template was the same size (44mm × 44mm) for both the 2mm and 4mm pixel images, and hence contained twice as many pixels for the 2mm case.…”
Section: Methodsmentioning
confidence: 99%
“…The fraction of lesions found (P LOC ) and area under the LROC curve (A LROC ) for each observer were also computed for each observer, and then averaged to obtain the final results. The methods used were the same as those previously developed and used for the Utah PET Lesion Detection Database Resource, and additional details can be found in [5, 6]. As with the CNPW observer results, a paired-sample Tukey HSD multiple-comparison test was performed to determine statistically-significant differences in A LROC for the different pixel sizes.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations