2015
DOI: 10.1016/j.ces.2015.05.013
|View full text |Cite
|
Sign up to set email alerts
|

Experimental characterization of vertical downward two-phase annular flows using Wire-Mesh Sensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(5 citation statements)
references
References 36 publications
(46 reference statements)
0
5
0
Order By: Relevance
“…Flow void fractions are collected by utilizing the Wire Mesh Sensor (WMS) while the values of pressure gradient are obtained by the Differential Pressure Transducer (PDT). The mentioned correlations above are used successfully to estimate the flow patterns by the researchers in [1], [10], [13], [15], and [28]. A comparison is performed between the result estimated by the WMS and PDT to assess the validation of using the PDT for identification flow patterns.…”
Section: Result Analysis and Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Flow void fractions are collected by utilizing the Wire Mesh Sensor (WMS) while the values of pressure gradient are obtained by the Differential Pressure Transducer (PDT). The mentioned correlations above are used successfully to estimate the flow patterns by the researchers in [1], [10], [13], [15], and [28]. A comparison is performed between the result estimated by the WMS and PDT to assess the validation of using the PDT for identification flow patterns.…”
Section: Result Analysis and Discussionmentioning
confidence: 99%
“…Wire Mesh Sensors (WMSs) and Differential Pressure Transducers (DPTs) were used in the current paper to identify the void fractions and the differential pressure drops of two-phase flow are improved as reliable sensors through numerous published papers such as [11], [12], [13], [14], [15]. While the Wire Mesh Sensor (WMS) is based on the analysis of void fractions to observe the phase distribution with a high resolution, the Differential Pressure Transducers (DPT) recorded the simultaneous pressure drops of two-phase flow in a specified distance along a pipe.…”
Section: Related Workmentioning
confidence: 99%
“…Godbole et al [191] conducted a comprehensive literature review of the void fraction correlations and experimental results in the early years of upward two-phase flow. Most area-averaged void fraction had an increasing trend along the axial direction and decreased after a maximum value of around 80-100 diameters downstream [144,145,148]. However, the decrease in void fraction in the vertical downward annular flow was also observed in some conditions which was a result of the kinematic shock phenomenon.…”
Section: The Void Fraction Of Annular Two-phase Flowmentioning
confidence: 91%
“…Using the wire-mesh sensor technology, they collected different flow properties, including the gas volume fraction, bubble size, and gas velocity. Vieira et al [144,145] used a dual WMS with a sampling frequency of 10 kHz to detect the local instantaneous crosssection distribution of the gas core in a vertical pipe. The dual sensor enables simultaneous measurements of the local void fraction at two positions along the flow direction and the flow velocity can be captured from the correlation of the two signals.…”
Section: Wire-mesh Sensor (Wms)mentioning
confidence: 99%
See 1 more Smart Citation